Combustion Catalog | Fives North American

Flame-Jet Gas Burners - Flame Characteristics

Sheet 4545-1

TABLE 1. Capacities, Stability Limits, Flame Lengths.

Flame Lengths with natural gas,

Stability limits without pilot

Air

Air

Burner

Pressure,

Capacity,

Excess Air (Lean Limit)

Excess Fuel (Rich Limit)

correct ratio,

size

osi

cfh

open cold furnace

4545-6

1

3,710 7,400

160% 130% 125% 120% 480% 420% 400% 330% 270% 250% 200% 200% 300% 370% 330% 200% 1500% 1500% 1400% 1300%

75% 78% 82% 73%

2.5' 3.0' 3.0' 3.0' 3.0' 4.0' 4.0' 4.0' 4.0' 4.5' 6.0' 6.0' 4.5' 5.5' 6.0' 6.0' 7.0' 7.0' 8.0' 9.0'

4 8

10,500 14,800

16

4545-7

1

6,550

100% 100% 100%

4 8

13,100 18,500 26,200 10,600 21,200 30,000 42,400 17,000 34,000 48,000 68,000 31,100 62,000 88,000 124,000

16

85%

4545-8-A

1

100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%

4 8

16

4545-8-B

1

4 8

16

4545-9

1

4 8

16

Note: Burner stability is influenced by the location of the combustion air inlet elbow. Maintain a minimum of four pipe diameters between air inlet flange and nearest elbow. TABLE 2. Flame Lengths at Various Ratios.

Burner

Air

size

Pressure, osi

230% Excess Air

Correct Ratio

100% Excess Fuel

4545-8-A

1

1.0' 1.0' 1.5' 1.5'

4.0' 4.5' 6.0' 6.0'

6.0' 9.0'

4 8

10.0' 10.0'

16

4545D MODELS. See Sheet 4545-2 for information on 4545D Burners (30% greater capacity). FLAME SAFEGUARD INFORMATION. See Sheet 8832-1

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com