Combustion Catalog | Fives North American

Dimensions | 4570 HiVAM™

"T" Connection, F Style

Bulletin 4570 Page 3

L

E

DIMENSIONS in inches

P

F

2 13⁄16

J

B -NPT Gas

A –pipe size

2 ½ NPT Atomizing Air

M

3 ¼

H

D

Main Air Flange

Q Flange Thickness

Burner

Slip-on Air Connection Actual Pipe OD Size

Air inlet flange dimensions

Designation

Flange Pattern

OD

B.C. # Holes Hole Ø

13.5

11.75 14.25

8

0.88 0.75

8 5⁄8 12 ¾

4570-9 4570-12

8" ANSI 12" RPM

16

12

"Y" Connection, SW Style

¾ NPT–Pilot UV

¾ NPT–pilot mixture 1 NPT–Main Flame Obs. (or UV)

R240-2802 Spark Electrode

E

L

(Same as above)

45°

OPTIONS 45° or 90° main air connection. Flanged or slip-on main air connection. When ordering, specify choice of options as follows: (P) for spark ignited pilot (E) for direct spark igniton (Y) for 45° air connection (T) for 90° air connection (F) for flanged air connection (SW) slip-on or welding air connection 1 NPT UV with 1  ¾ hex bushing

K

A –pipe size

G

Main Air SW Style Slip-Fit or Welding Conn.

Example:

4570-9-EYF burner complete with direct spark, 45° air connection and flanged air connection.

4570 HiVAM ™ s for gas only have the same dimensions and practically the same weights as 6570 HiVAMs since the gas burners also have an "atomizing air" connection for greater flame stability.

Burner

dimensions in inches

Approx.

designation A B D

E

F

G H J

K

L

M

P

Q 3⁄8 ½

lb

4570-9 4570-12

8 2 ½ 16 1⁄16 15 13⁄16 3 ¾

29 15⁄16 7 7⁄8

8 11 5⁄16

15 13⁄16 23 13⁄16

23 7⁄8

8 5⁄8

125

12

3 19 13⁄16 21 5⁄16

4 ¾

42 13⁄32 8 12 14 27⁄32

34 5⁄8 11 ¾

200

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker