Engineering Data | HiRAM ® Medium Velocity

Main Air Pressure, osi/"w.c./mbar

4575-12

0.2 0.3 0.9

1

4

9

16

osi "w.c. mbar

1.7

6.9 17.2

15.6

27.7

with MV tile

4.3

39

69

Main Air Flow, not burning, scfh (Nm 3 /h) Main Air Flow, burning, stoich., scfh Main Air Flow, burning, stoich, Nm 3 /h Gas Pressure, stoich, "w.c. (mbar) Gas Pressure, 10% excess air, "w.c. (mbar) Maximum %XSAir with flame signal (UV)

231 000 (6175)

20 990

48 940

100 500

151 100 (4039)

208 350

(561)

(1308)

(2686)

(5569)

0.1 (.25) 0.1 (.25)

0.8 (2.0) 0.75 (1.9)

4.0 (10.0) 3.2 (8.0)

8.0 (19.9) 7.0 (17.4)

13.5 (33.6) 12.3 (30.6)

800

2500

2000

1400

1200

Maximum %XSFuel

30

30

30

30 — —

30 — —

Maximum %XSAir, ignition--pilot

800 800

2500 2500

600 600

Maximum %XSAir, ignition--direct spark

Flame Length, stoich., ft. (Meter) Flame Diameter, stoich., in. (mm)

9.0 (2.7) 48 (1219)

11.0 (3.4) 38 (965)

13.0 (4.0) 36 (914)

14.0 (4.3) 36 (914)

14.0 (4.3) 48 (1219)

Main Air Pressure, osi/"w.c./mbar

4575-14

0.2 0.3 0.9

1

4

7

9

osi "w.c. mbar

1.7

6.9 17.2

12.1

15.6

with MV tile

4.3

30

39

Main Air Flow, not burning, scfh (Nm 3 /h) Main Air Flow, burning, stoich., scfh Main Air Flow, burning, stoich, Nm 3 /h Gas Pressure, stoich, "w.c. (mbar) Gas Pressure, 10% excess air, "w.c. (mbar) Maximum %XSAir with flame signal (UV)

314 000 (8393)

36 000

93 400

181 000 (4838) 2.0 (5.0) 2.0 (5.0)

252 000

297 000 (7939) 4.0 (10) 4.0 (10)

(962)

(2497)

(6736)

0.0

0.0 0.0

3.6 (9.0) 3.5 (8.7)

-0.1 (-.25)

1500

1500

1500

1250

1250

Maximum %XSFuel

30

30

30

30

30 — —

Maximum %XSAir, ignition--pilot

1500

1500 200

1500 — 400 —

Maximum %XSAir, ignition--direct spark

100

Flame Length, stoich., ft. (Meter) Flame Diameter, stoich., in. (mm)

10 (3.0) 36 (914)

14 (4.3)

17 (5.2)

17 (5.2)

19 (5.8)

48 (1219)

60 (1524)

60 (1524)

60 (1524)

Medium Velocity (MV) HiRAM burners vs. Original High Velocity (HV) HiRAM

The medium velocity tiles available for the 4575-burner family have no tile exit restriction, so the velocity of the flame exiting the tile will be 25-50% lower than a standard 4575 burner with a high velocity tile. This also means that the tile backpressure and burner air pressure requirements are much lower. A medium velocity 4575 operating at 7-10 osi air pressure will have the same capacity as the high velocity burner at 16 osi.

To estimate performance for the 4575 MV burners not listed above: — MV burner air capacity at 9 osi = HV burner at 16 osi air pressure

— MV burner flame length = 30% longer than HV burner at the same capacity — MV burner gas pressure = 50% lower than HV burner at the same capacity — Excess air, lighting, and flame supervision limits should be the same as HV burner at the same capacity

Bulletin 4575 Page 10