Capacities | reGen ® Gas Burners
Table 1. 4630 CAPACITIES and DRILLINGS
Input @ 4"w.c./ 10 mbar mixture pressure per ft/12"/305 mm each outer row inner row Drilling
Heat Input Range minimum to maximum per foot/12"/305 mm
4630 Burner Designation suffix
Btu/H HHV
kW LHV
Drill Size
# of holes/ft
Drill Size
# of holes/ft 0.35"w.c.
Btu/h HHV kW LHV
12"w.c. 32 000 39 000 50 000 65 000 77 000 98 000 122 000 147 000
0.9 mbar 30 mabr
19 23 29 36 45 57 71 85
19 000 23 000 29 000 36 000 45 000 57 000 71 000 85 000 101 000 119 000 144 000 169 000 198 000 226 000 252 000 289 000
5.02 6.08 7.66 9.51 11.9 15.1 18.8 22.5 26.7 31.4 38.1 44.7 52.3 59.7 66.6 76.4
49 45 45 45 45 45 45 42 42 42 42 42 42 42 42 42
12 12 12 12 23 23 23 23 23 23 23 23 23 23 23 23
- -
- -
6000 7000 9000
1.59 1.85 2.38 2.91 3.70 4.49 5.81 6.87 7.93 9.51 11.4 13.2 15.6 17.7 19.8 22.7
8.46 10.3 13.2 16.4 20.3 25.9 32.2 38.8 46.0 54.4 65.8 77.2 90.4 103 115 132
53 53
11 22
11 000 14 000 17 000 22 000 26 000
-
-
53 46 45 38 31 25 19 13
22 22 22 22 22 22 22 22 22 22 22
101 119 144 169 198 226 252 289
30 000 174 0000
36 000 43 000 50 000 59 000 67 000 75 000 86 000
206 000 249 000 292 000 342 000 391 000 436 000 500 000
5 1 3
Drillings are different for the elbows in some larger sizes, but capacities per foot are the same. Mixture manifolds should not be larger than 4" pipe size because of flashback hazard.
4630 SELECTION
1. Sketch (to scale) a burner layout that will provide uniform temperature distribution. 2. Determine total burner length this layout requires by adding together individual section lengths as indicated below. The “typical” large assembly on Page 1 covers 3 ft. square (or about 1 M square) (6) 4630-E (12") and (4) 4630-S (3") straight sections (2) 4630-T tee section (1) 4630-X cross section (1) 4630-P pilot section (3) 2" inlet flanges This results in 12' of total “burner length.” 3. Divide total Btu/h HHV input requirement by total burner length. Result will be Btu/h HHV per ft of 4630 Burner. Select appropriate burner capacity/drilling from Table I...at the 4"w.c. (10 mbar) mixture pressure ratings shown, or higher or lower ratings if other mixture pressures are available (up to 12"w.c. (30 mbar) maximum)--use the square root law or handbook tables for determining different ratings.
4. Select points at which air-gas mixture is to be fed into assembly: A 2" end connection can handle up to 350,000 Btu/h HHV (at 4"w.c.). A 3" connection can handle 800,000 Btu/h HHV (4630-B, -H, area, using: -T, and -X have 3" connections). If multiple inlet connections are required, locate them so they feed approximately equal burner lengths. If multiple mixers are used, mixer zones must be separated within burner assembly use either 4-1739-1 separator plates or 4-3159-1 expansion ignition couplings. 5. “Fill in” assembly with appropriate straight and elbow section, inlet flanges, end plates, etc. 6. To avoid dangerous flashback, mixture manifolds should not exceed 4" pipe size. 7. Use the instructions in bulletin 3065 to chose the correct mixer sizes.