Mounting & Tile Dimensions | Premix Gas Burner Nozzles
optional 88––-H Flame Detector Adapter
H°
Mounting
Tile
F
T– dia. Pilot hole
K dia.
L sq.
J dia.
S
Nozzle
P– dia. 4 holes on N–BC
M dia.
C
B
A
D
4682-0 through -7
Table 3A
Dimensions in inches (mm) and degrees
Tile
MTD. Part #
wt. lb (kg)
A B C D E F G H°
J
K L
M N P R°
S T Part #
4682-0- MP*
2.06 (52)
2.63 (67)
5.50 (140)
4.69 (119)
2.06 (52)
0.50 (13)
1.94 (49)
1.75 (44)
3.00 (76)
5.00 (127)
6.00 (152)
5.25 (133)
0.44 (11)
0.63 (16)
1.03 (26)
12 (5.2)
25°
40°
4-2653-1
4682-1- MP
1.94 (49)
2.63 (67)
7.00 (178)
4.56 (116)
2.06 (52)
0.50 (13)
1.94 (49)
2.31 (59)
4.00 (102)
6.00 (152)
6.00 (152)
5.25 (133)
0.44 (11)
0.63 (16)
1303 (26)
20 (9.1)
25°
40°
4-2653-2
4682-2- MP
2.06 (52)
2.88 (73)
7.00 (178)
4.94 (125)
2.25 (57)
0.50 (13)
2.13 (54)
2.31 (59)
4.00 (102)
6.00 (152)
6.50 (165)
5.75 (146)
0.44 (11)
0.88 (22)
1.03 (26)
20 (9.1)
25°
45°
4-2653-2
4682-3- MP
2.00 (51)
3.56 (90)
8.00 (203)
5.56 (141)
2.31 (59)
0.50 (13)
2.81 (71)
2.75 (70)
4.50 (114)
7.00 (178)
7.50 (191)
6.75 (171)
0.44 (11)
1.00 (25)
1.03 (26)
32 (15)
30°
40°
4-2653-3
4682-4- MP
1.44 (37)
4.00 (102)
9.00 (229)
5.44 (138)
3.00 (76)
0.56 (14)
2.44 (62)
3.38 (86)
5.50 (140)
9.00 (229)
8.75 (222)
7.75 (197)
0.56 (14)
1.25 (32)
1.03 (26)
60 (27)
30°
40°
4-2653-4
4682-5- MP
1.81 (46)
4.31 (109)
9.00 (229)
6.13 (156)
3.38 (86)
0.56 (14)
2.69 (68)
4.00 (102)
6.00 (152)
9.00 (229)
9.75 (248)
8.75 (222)
0.56 (14)
1.38 (35)
1.03 (26)
60 (27)
30°
40°
4-2653-5
4682-6- MP
2.44 (62)
4.81 (122)
9.00 (229)
7.25 (184)
4.00 (102)
0.56 (14)
2.88 (73)
4.00 (102)
6.00 (152)
9.00 (229)
11.00 (279)
10.00 (254)
0.56 (14)
1.75 (44)
1.14 (29)
60 (27)
30°
40°
4-2653-5
4682-7- MP
2.50 (64)
5.75 (146)
10.94 (278)
8.25 (210)
4.81 (122)
0.69 (18)
3.06 (78)
6.00 (152)
11.44 (291)
15.13 (384)
13.50 (343)
12.25 (311)
0.56 (14)
2.31 (59)
1.14 (29)
115 (52)
30°
40°
4-2653-6
4682-0 Nozzle uses 4682-1-MP Mounting. If tunnels are to be rammed in furnace wall, use dimension "J" at entrance, and taper tunnel at least 15°. Space nozzle about 2" (50 mm) from outer face of wall.
Recommended pilot tip for the 4682-0-MP through 4682-5-MP = 4021-14 with 1" (25.4 mm) slip-fit connection Recommended pilot tip for 4682-6-MP and 4682-7-MP = 4021-16 with 1 1/8 " (28.6 mm) slip-fit connection
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .
Bulletin 4682 Page 6