Combustion Catalog | Fives North American

Mounting & Tile Dimensions | Premix Gas Burner Nozzles

optional 88––-H Flame Detector Adapter

H°

Mounting

Tile

F

T– dia. Pilot hole

K dia.

L sq.

J dia.

S

Nozzle

P– dia. 4 holes on N–BC

M dia.

C

B

A

D

4682-0 through -7

Table 3A

Dimensions in inches (mm) and degrees

Tile

MTD. Part #

wt. lb (kg)

A B C D E F G H°

J

K L

M N P R°

S T Part #

4682-0- MP*

2.06 (52)

2.63 (67)

5.50 (140)

4.69 (119)

2.06 (52)

0.50 (13)

1.94 (49)

1.75 (44)

3.00 (76)

5.00 (127)

6.00 (152)

5.25 (133)

0.44 (11)

0.63 (16)

1.03 (26)

12 (5.2)

25°

40°

4-2653-1

4682-1- MP

1.94 (49)

2.63 (67)

7.00 (178)

4.56 (116)

2.06 (52)

0.50 (13)

1.94 (49)

2.31 (59)

4.00 (102)

6.00 (152)

6.00 (152)

5.25 (133)

0.44 (11)

0.63 (16)

1303 (26)

20 (9.1)

25°

40°

4-2653-2

4682-2- MP

2.06 (52)

2.88 (73)

7.00 (178)

4.94 (125)

2.25 (57)

0.50 (13)

2.13 (54)

2.31 (59)

4.00 (102)

6.00 (152)

6.50 (165)

5.75 (146)

0.44 (11)

0.88 (22)

1.03 (26)

20 (9.1)

25°

45°

4-2653-2

4682-3- MP

2.00 (51)

3.56 (90)

8.00 (203)

5.56 (141)

2.31 (59)

0.50 (13)

2.81 (71)

2.75 (70)

4.50 (114)

7.00 (178)

7.50 (191)

6.75 (171)

0.44 (11)

1.00 (25)

1.03 (26)

32 (15)

30°

40°

4-2653-3

4682-4- MP

1.44 (37)

4.00 (102)

9.00 (229)

5.44 (138)

3.00 (76)

0.56 (14)

2.44 (62)

3.38 (86)

5.50 (140)

9.00 (229)

8.75 (222)

7.75 (197)

0.56 (14)

1.25 (32)

1.03 (26)

60 (27)

30°

40°

4-2653-4

4682-5- MP

1.81 (46)

4.31 (109)

9.00 (229)

6.13 (156)

3.38 (86)

0.56 (14)

2.69 (68)

4.00 (102)

6.00 (152)

9.00 (229)

9.75 (248)

8.75 (222)

0.56 (14)

1.38 (35)

1.03 (26)

60 (27)

30°

40°

4-2653-5

4682-6- MP

2.44 (62)

4.81 (122)

9.00 (229)

7.25 (184)

4.00 (102)

0.56 (14)

2.88 (73)

4.00 (102)

6.00 (152)

9.00 (229)

11.00 (279)

10.00 (254)

0.56 (14)

1.75 (44)

1.14 (29)

60 (27)

30°

40°

4-2653-5

4682-7- MP

2.50 (64)

5.75 (146)

10.94 (278)

8.25 (210)

4.81 (122)

0.69 (18)

3.06 (78)

6.00 (152)

11.44 (291)

15.13 (384)

13.50 (343)

12.25 (311)

0.56 (14)

2.31 (59)

1.14 (29)

115 (52)

30°

40°

4-2653-6

4682-0 Nozzle uses 4682-1-MP Mounting. If tunnels are to be rammed in furnace wall, use dimension "J" at entrance, and taper tunnel at least 15°. Space nozzle about 2" (50 mm) from outer face of wall.

Recommended pilot tip for the 4682-0-MP through 4682-5-MP = 4021-14 with 1" (25.4 mm) slip-fit connection Recommended pilot tip for 4682-6-MP and 4682-7-MP = 4021-16 with 1 1/8 " (28.6 mm) slip-fit connection

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

Bulletin 4682 Page 6

Made with FlippingBook flipbook maker