Combustion Catalog | Fives North American

Dimensions | 4821 Air Burners

FF - Diameter linning

P - Diameter

DIMENSIONS in inches

H - bolt circle

DD R tile only exit diameter

E - Diameter F - # of holes

J - Diameter

K - Diameter L - # of holes

N - bolt circle

 BB - Minimum tile length

 B - 150 ANSI raised flange gas inlet

A - Main air connection (ANSI)

2 .50

V

W

X

½

AA - NPT pilot conn. 45° to mfg. fl ange

¼" NPT fuel tap

.50 mounting fl ange

T

U

¼" NPT air tap

1" NPT for flame detector 45° to mfg. fl ange

 CC dia

BB dia

C - NPT jet air inlet

1" NPT obs. port conns.

Z - Obsrv. port

 BB - Minimum tile length 3° taper for standard tile only

S - Diameter

EE - Clearance reqd. to remove internals Y

D - Hole on a R - Bolt circle Q - # of holes (straddle centerline)

DIMENSIONS IN INCHES AND DEGREES

Burner Designation A

B 

C

D

E

F

G °

H J

K

L M °

N

P

Q

R

S

T

4821-9

8

2.5 1 2.5 1 2.5 1

0.75 0.75 0.75 0.75 0.75

0.75 4 0.75 4 0.75 4 0.75 4 0.75 8 0.75 8

45 45 45 45

5.5 7 5.5 7 5.5 7

0.88 8 22.5

11.75

13.5

16 20.5 16 20.5

22.25 22.25

11.75 11.75

4821-10-A 4821-10-B

10 10 12 14 16 18 20 22

1 1

12 12 12

15 15 15 15

14.25 16 14.25 16

16 16

22.5 24.5

24.25 13.75 26.25 14.75 28.25 14.81 30.25 14.81 32.25 14.81

4821-12 4821-14 4821-16 4821-18 4821-20 4821-22

3 4 4 4 6 6

1 1

6

7.5 1

17

19 21

22.5 7.5 9 22.5 7.5 9 22.5 7.5 9 22.5 9.5 11 22.5 9.5 11

1.13 12 1.13 16 1.25 16 1.25 20 1.25 20

18.75

20 26.5

1¼ 0.75

11.25 21.25 23.5 20 28.5

2 0.88 0.75 8 2 0.88 0.88 8 2 0.88 0.88 8

11.25 22.75 25

20 30.5

9 9

25 26

27.5 24 32.5 29.5 24 34.5

34.25 36.25

15.5 15.5

DIMENSIONS IN INCHES

Burner

Estimated Recommended

AA BB 

CC  DD 

Designation

U

V

W

X

Y

Z

EE

FF

weight, lb

pilot assy.

4821-9

11 11

13

12.31 5.75

33.56 33.56 37.19 42.25 45.56

1.5 1.5 1.5

10 10

16 16 18 20 22 24 26 28 30

5.75 6.25

60

7 9 9 11

343 343 443 580 715 795 915 1035 1152

4014-2-T 4014-2-T 4014-2-T 4014-3-AT 4014-3-AT 4014-3-AT 4014-3-BT 4014-3-BT 4014-3-BT

¾ ¾ ¾ ¾ ¾

4821-10-A 4821-10-B

12.25 13.06 5.75

61

12.5 13.5 14.5 15.5 16.5 17.5 18.5

15

13.94 5.75 15.44 6.81 16.88 7.69 17.25 7.31 18.88 7.5 21.25 8.88

11

7

69 83 86 87 92

4821-12 4821-14 4821-16 4821-18 4821-20 4821-22

17.5 18.5

2 2 2 2 2 2

12.5

8.5

14.75

10

13.63 15.63 17.63 19.63 21.63

19

46.06 2 48.38 2

17

11.25 12.75 14.25 15.75

19.5 20.5 21.5

19.25

53.13

2 2

21.5

100 100

23.13 8.88 56

24

 Furnace opening should be ½" larger than dimension CC for 10A thru 14 and ¾" larger than dimension CC for 16 thru 22.  Whenever the tile length is greater than BB × 1.2, the tile beyond BB should flare out at a 30° angle (60° included angle).  Flat face companion flange available upon request.  Max capacity at "DD" is as shown in 1000°F column in capacity table. Consult engineering for R-tile use at higher capacities.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

Bulletin 4821 Page 3

Made with FlippingBook flipbook maker