Sheet 4832-3
North American Low NOx Standard Flat Flame TM Gas Burners - Ordering Procedur e
Product code prefixes will no longer be used to identify tile and mounting assemblies. Tile and mounting assemblies will be identified by part number only. See Sheet 4832-5. "Z" dimension on Z-type tiles is now specified in the configuration.
4832 (Complete Burners only)
(Use 4832D for 13" deep tiles.)
- - /
4832
Tile material suffix 30 = 3000 F dense castable* 32 = 3200 F dense castable with 310 SST needles (1 ½ % by weight)† For pre-fired and special castable materials, consult factory.
Burner designation
For typical hard wall and roof construction: T = square mounting and tapered tile (tapered - two sides only) SG = square mounting and tile with grooves RG = round mounting and tile with grooves RGF = round flanged mounting and tile with grooves (-8-A and -8-B only) [See Sheet 4832-6, page 2.] SGR = square mounting and roof tile with grooves RGR = round mounting and roof tile with grooves (-8-A and -8-B only)
Code pipe size - main air 2 = 1 ¼" 3=1½" 4 = 2" 5=2½"
Type of Mounting
6 = 3" 7 = 4"
and Tile
8-A = 6" 8-B = 6"
For typical fiber wall construction: RZ = round tile and mounting dimension. "Z" dimension
"Z" dimension available between 2" and 15 ½ " in ½ " increments.‡
from flange to hot face
SZ = square tile and mounting dimension. "Z" dimension from flange to hot face
"BO" means Burner Only--no tile designation required.