Sheet 4832-3 page 2
Examples: 4832-4-SG/30
2" Burner complete with 3000°F, 13 ½ " square grooved 9" deep tile and square, cast flangeless mounting. 2 ½ " Burner complete with 3200°F, 13 3⁄8 " diameter round, grooved 13" deep tile and round, cast flangeless mounting. 3" Burner complete with 3000°F, 9" deep square tile and flanged fabricated mounting. Must specify "Z" dimension as part of configuration. 2" Burner complete with 3200°F, 13" deep round tile and flanged fabricated mounting. Must specify "Z" dimension as part of configuration. 1 ½ " Burner only.
4832D-5-RG/32
4832-3-BO
4832-6-SZ/30
4832D-4-RZ/32
4832-7-SGR/32 4" Burner complete with 3200°F, 24" square grooved 9" deep tile and square, cast flangeless mounting and four hanger rod assemblies for roof mounting. 4832-8-A/SGR/32 6" Burner complete with 3200°F, 20" square grooved 9" deep tile and square, cast flangeless mounting, and four hanger rod assemblies for roof mounting. 4832D-8-B/RGR/32 6" Burner complete with 3200°F, 21" diameter round grooved 13" deep tile and round cast flangeless mounting, and four hanger rod assemblies for roof mounting.
Formerly 4836
* Not available in 4832 roof-mounted burners--must specify 3200°F material. † 4832 roof tiles and tiles rated for 3200°F service temperature are supplied with this construction. ‡ For "Z" 9, a 9" deep tile is supplied. For "Z" 9, a 13" deep tile is supplied. The tile may therefore extend back beyond the mounting flange. See page 2 of the 4832 Dimensions Sheet to calculate the flange to main air connection distance once a "Z" dimension is chosen.
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com