North American Low NOx Flat Flame TM Burners Special Mountings
Sheet 4832-6
4832B SUSPENSION ARRANGEMENTS for 4832-2 through -7 and 4832D-2 through -7
½ -13 36" long threaded rods (2 required)
4832B suspension arrangement permits roof mounting of conventional 4832 and 6832 burners with small tiles and flangeless mountings, especially where space limitations do not permit use of large "roof" tiles.
B
A
39"
Ordering and Dimensional Information
Part
Pilot and UV
number *
A
B
location
4832-2 thru -7 with square tiles with round tiles
between brackets }
4832BS 4832BR
5 ½
11
10" or 14"
4 15⁄16
9 7⁄8
* Provides complete set of parts for one burner as shown.
HARD WALL MOUNTING FLANGES for 4832-2 through -7 and 4832D-2 through -7
5⁄8 dia. –8 holes
Mounting Flange 3⁄16
Flange 9" Tile 13" Tile
Part No. 4-41336-1 4-41336-2 4-41336-3 4-41336-4 4-41336-5 4-41336-6 4-41336-7 4-41336-8
L
L
Burner Tile
10
14
8 ¾
10 ½
14 ½
Burner Mounting
Point "A"
7 ½
11
15
11 ½ 10 ¼ 10 ¾ 11 ¼ 11 ¾
15 ½ 14 ¼ 14 ¾ 15 ¼ 15 ¾
7 ½
8 ¾
13 ½ sq.
As nearly flush as possible but burner tile must not be recessed in opening
Length "L" 10 " min. 11 ¾ " max. ( 9 " tile) 15 ¾ " max. ( 13 " tile)
7 ½
7 ½
Furnace shell with 14 " sq. opening
8 ¾
8 ¾
4832 Wall Mounting Flanges (see part no. in table) allow bolting 4832 and 6832 Burners to steel furnace shells with refractory walls. They do not provide a pressure-tight seal against furnace gas leakage. Custom-made flanges are assembled to burner mountings by Fives to customer-specified dimension "L" so tile hot face is flush with inside furnace wall. "L" can be increased up to 3⁄8 " in the field by inserting flat washers at point "A" (see above drawing).