Product Overview | 4831 Flat Flame ™
Construction. Burner bodies are made of cast iron. The standard 60% alumina refractory tile, suitable for furnaces up to 3000 °F (1650 °C), is available in 7" (178 mm) and 9" (229 mm) lengths. The refractory cover plate should not be attached to the furnace shell. Tiles, tapered on two sides, are available in the 9" (229 mm) length only. These tile faces measure 6.75 (172 mm) x 7.50“ (191 mm). Specify “4831- -T”. Installation. Burner tile face must be flush with the inside surface of the furnace refractory. For convenience in piping burners in thick walls, air and gas connections enter the back of the burner parallel to its centerline. Two studs projecting from the cover plate permit suspending the burner in a furnace roof. For more comprehensive instructions, refer to Instructions in Bulletin 4832. Flame Supervision. Burners are compatible with certain makes and models of flame supervisory equipment. Consult a North American office for a satisfactory arrangement. Viewed from outside the furnace, flame detector must be mounted clockwise from the pilot. The burner is shipped with an observation port in the detector opening. Consider using a 8838-E-UV combo UV flame detector/ observation port. This unique adapter provides for flame supervision and flame observation in a single 3/4 " burner port. See Bulletin 8832 for details.
4831 Flat Flame Burners transfer heat to the surrounding refractory wall or roof by highly turbulent convection; the refractory then radiates heat uniformly to the load. Minimum forward velocity results in uniform radiant heating with no flame impingement.
Applications. Successful applications of 4831 Flat Flame Burners include:
Wire patenting furnaces: Roof-mounted burners provide more uniform heating than side-fired installations.
Cover annealers: The excellent uniformity and fuel econo- my characteristic of large cover annealing furnaces fired with 4832 Flat Flame Burners have been duplicated with 4831’s on smaller units.
Strip annealers: The 4831’s small diameter flame is ideally suited to long narrow furnaces.
High temperature single layer kilns.
Glass tank forehearths.
Performance. 4831 Flat Flame Burners are sealed-in. All combustion air is provided through the air connection. They are stable in cold, tight chambers, operating lean, rich, or on correct ratio. This flexibility combines with flat flame characteristics to produce superior uniform heating. Flames stay flat down to 1 osi/1.7"w.c./4.3 mbar air pressure on correct air/gas ratio but are less flat with rich ratios. Even when visible flames are within the tile throat, flow of combustion products is still flat.
Lighting. Series 4831 Burners light smoothly with North American gas pilots. Limit pilot input to 10 000 Btu/h HHV (2.9 kW) to avoid overheating the mounting. Interrupted pilots are required for maximum safety. For Direct Spark Ignition the 4055-A may be used. Manual lighting with a torch also is possible, either at the tile face or through the pilot opening in the burner. Pilot opening must be closed after lighting.
Bulletin 4831 Page 2