Dimensions | 4831 Flat Flame ™
DIMENSIONS inches (mm)
45°
3/4" NPT Pilot or Igniter Port
2.88 (73)
4831- -T is Tile is tapered on two sides to 6 3/4" width at tile face.
2.0 (51)
.38 (10)
3/8" -16 NC THD.
3.63 (92)
30° X2
3/4" NPT FS or OBS Port
7.50 (191) square
2.75 (70)
A–NPT Main Air Connection
1.91 (48)
1.75 (44)
1.0 (25)
1/8" NPT Air Pressure Tap
B–NPT Gas Connection
9.25 (235)
7.13 (181)
3.66 (93)
or
With pilot and flame detector bosses in position shown, gas inlet can be positioned at either 6 or 9 o'clock positions.
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
Dimensions and Accessories (order separately)
Burner
NPT
-7"/-9" Tile Recommended Pilot Mixture
Direct
Combo(#)
Flame
Size
A B wt. lb (kg) Pilot Set/Pilot Set
Pressure Spark Igniter UV/OBS Port
rod
4831-0 4831-1
3/4
1/2 3/4
44/52 (20/24)
0.8"w.c. (2.0 mbar)
822F4-0-3.5 3.50" (89 mm)
4011-12/4021-12
4055-A
8838-E-UV
1
Notes: (#) Other UV flame detectors can be used, but the 8838-E-UV retains the observation port. See Bulletin 8832 for details (4) 3.50 inches (89 mm) From the outer boss of the flame rod connection. UV flame detectors are generally more reliable than flame rods in flat flame burners, and do not work in most 4832 burners.
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
Bulletin 4831 Page 4