Combustion Catalog | Fives North American

Dimensions 4987 Page 2

ORDERING INFORMATION

4 9 8 7 - __ __ __ __ - __ __ __

Capacity 50 = 500,000 Btu/hr 100 = 1,000,000 Btu/hr 250 = 2,500,000 Btu/hr

Tile Option blank - 800°F S - 1200°F (304 SST) Fuel Option blank - natural gas P - propane B - butane

Control Option 1 - manual air setting with remote fuel flow control 2 - manual air setting with fuel flow control on burner 3 - linked air and fuel flow control on burner

Blower Option L - blower develops 1" static pressure H - blower develops 3 to 5" static pressure R - remote blower (pipe connection)

Examples: 4987-501-HP Denotes 500,000 Btu/h HHV burner with manual air setting and remote fuel flow control, 3" static pressure blower, and propane fuel. 4987-2503-LS Denotes 2.5 million Btu/hr burner with linked air and fuel flow control, 1" static pressure blower, natural gas fuel, and a 304 stain- less tile for 1200°F application.

ACCESSORY Part Numbers Blower Filter*

500-L

500-H

1000-L

1000-H

2500-L

2500-H

washable filter assembly disposable filter assembly replacement (washable) replacement (disposable)

4-27063-1 4-27063-5 R260-2160 R260-2900

4-27063-2 4-27063-6 R260-2160 R260-2900

4-27063-1 4-27063-5 R260-2160 R260-2900

4-27063-2 4-27063-6 R260-2160 R260-2900

4-27063-3 4-27063-7 R260-2240 R260-2910

4-27063-4 4-27063-8 R260-2240 R260-2910

Actuator Mounting Kit* † (for direct coupled mounting) for Honeywell mod motors

4-27069-1 4-27069-2 4-27069-3

for Siemens SQM5...actuators

for Barber Colman EA50 series actuators

Burner Mounting Plate* ‡

4-27066-1 (500 size)

4-27066-2 (1000 size)

4-27066-3 (2500 size)

Flame Protection Tube* ‡ 304 stainless steel

4-28174-1 (500 size) 4-28174-2 (500 size)

4-28175-1 (1000 size) 4-28175-2 (1000 size)

4-28156-1 (2500 size) 4-28156-2 (2500 size)

309 stainless steel

Notes * Accessories are shipped separately. Contact North American for special pre-assembled options. † Kit consists of bracket, coupling and hardware to mount actuator. Kit dœs not include actuator (sold separately). For actuators not indicated above, contact North American for pricing and delivery. ‡ Consult North American for overall size and mounting hole pattern. WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com