Dimensions | 4988 Zephyr™
OPTIONAL EQUIPMENT with DIMENSIONS, inches
Pressure taps ¼ " NPT air
E
F
C
Filter for 4988-1000, -2500, -4000, and -6000-L D A B
Filter Assemblies, optional for 4988 Burn- ers, use inexpensive throwaway panel filters to clean air entering Zephyr blowers. On 4988-1000, -2500, -4000, and -6000-L Burners, filter housing completely encloses blower and motor; pressure taps and a conduit knockout on the housing permit connections to blower and motor. Filters for -6000-H and -9000-L Burners attach to blower inlet. Filters are shipped loose for field installation.
E
filter can be rotated 90°
7 ¾ "
6 9⁄16 "
C
7 ¾ "
D
A
B
Filter for 4988-6000-H and -9000-L
no. of fi lter
dimensions in inches
filter elements only
filter assembly for 4988
A
B C
D E F panels filter size
(panels)
4-5676-1 filter assembly for -1000-L & -H 4-5683-1 filter assembly for -2500-L & -H
20" 20" 2" 20" 20" 2" 20" 25" 2" 20" 25" 2"
13 1⁄8 20 ¼ 20 ¼ 23 ¾ 13 6
1 1
R260-3241 R260-3241 R260-3242 R260-3242
17 1⁄8
22 ¼ 20 ¼ 32 ¾ 15
7
4-5687-1 filter assembly for -4000-L & -H and -6000-L 20 ½ 25 ½ 24 1⁄8 38 3⁄8 16 9 2
4-5968-1 filter assembly for -6000-H and -9000-L
40 7⁄8 10 1⁄8 25 ½ 2 11⁄16 14 5⁄8 –
3
A sq.
Adapter plates simplify mounting circular Zephyr flanges to square duct cutouts. All plates are 3⁄16 " thick steel.
C
C
D E
D
adapter plate for 4988-
dimensions in inches
A
B
C
D
E
F G
H
part no.
½ ½ ½ ¾
8 7⁄8
1000 2500
14 7
4 5⁄16
— — —
12 12 12 16
4-5506-1 4-5506-2 4-5506-3 4-6012-1
5⁄16 5⁄16 5⁄16 9⁄16
B
E
19 9 ½ 23 11 ½ 31 15 ½
6
12 15⁄16
4000 & 6000
7 5⁄16 7 3⁄8
17
7 3⁄8
9000
23
" F " no. of " G " dia. holes
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .
Bulletin 4988 Page 3