Combustion Catalog | Fives North American

Spare Parts List | 4988 Zephyrâ„¢

Bulletin 4988 Page 7

blower assembly

flame cone

spark igniter

ignition cable and igniter assembly

ignition cable (5' long)

flame rod

air tube

adjustable low fire gas valve

assembly of body and legs

Description

4988-1000

4988-2500

4988-4000

4988-6000

4988-9000

Assembly of body & legs

4-5398-2 4-5427-1 4-5497-1 4-28010-1 4-5563-3 R930-9873

4-5487-2 4-5471-1 4-5497-2 4-28010-2 4-5563-3 R930-9873

4-5452-2 4-5486-1 4-5497-3 4-28010-3 4-5563-3 R930-9873

4-5452-2 4-5465-1 4-5497-3 4-28010-3 4-5563-3 R930-9873

4-5752-1 4-5760-2

Flame cone Flame rod

n/a n/a

Ignition cable & igniter assembly

Ignition cable (5' long)

4-5563-3 R930-9873

Low fire gas valve

Spark igniter*

4-5635-1

4-5635-1

4-5635-1

4-5635-1

4-5635-1

Air tube (natural gas) Air tube (propane)

4-5413-1 4-5949-1 4-5725-1

4-5463-1 4-5548-1 4-5680-1

4-5448-1 4-5513-1 4-5704-1

4-5448-1 4-5513-1 4-5704-1

4-5845-1 4-5845-1 4-5845-1

Air tube (butane)

Low pressure 4988- -L Blower assembly including motor (-L) Blower motor 230/460/3/60 (-L)

4-5551-1

4-5551-2

4-5551-3

4-5551-4

4-5803-5

N.33-B36T2SF

T1.0-B36T2SF

T1.0-C18T2SF

T1.5-B18T2SF

T3.0-C36T2SF

XXXXXXXXXX 190/380/3/50 Blower impeller (-L)

R340-5152

R340-5170

R340-5162

R340-5165

R340-5171

High pressure 4988- -H Blower assembly including motor (-H) Blower motor 230/460/3/60 (-H)

4-5803-1

4-5803-2

4-5803-3

4-5803-4

n/a

T.50-B36T2SF

T2.0-B36T2SF

T3.0-C36T2SF

T3.0-C36T2SF

n/a

XXXXXXXXXXX190/380/3/50 Blower impeller (-H)

R340-5157

R340-5160

R340-5161

R340-5171

n/a

*Note: This is a special vented spark plug. Using an unvented plug will result in frequent fouling and create lighting problems.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker