Combustion Catalog | Fives North American

GHV / GMV / GLV Gas Burners Bulletin 1.3 August 2009

Fives North American Combustion UK, Ltd.

GHV / GMV / GLV – Features  Velocities up to 150m/s  Short flame lengths  High stoichiometric turndown  Ideal for sequential firing  Suitable for most commercial fuel gases  Choice of silicon carbide, alloy or refractory firing tubes  Robust construction  Pre-heated air up to 350°C as standard  Standard direct spark ignition and flame rod supervision – UV option available An optional burner construction (to be specified at time of order) allows the use of pre-heated combustion air up to 350°C. GHV burners have high velocity tiles for a combustion exit velocity of up to 150m/s. GMV burners provide exit velocity of up to 100m/s, GLV up to 50m/s.

Standard GHV, GMV and GLV burners use silicon carbide firing tubes which are suitable for most applications up to 1400°C. For temperatures to 1000°C they may be fitted with alloy firing tubes. Thick furnace walls may use extended firing tubes – contact FNAC for application-specific details. Refractory castable tiles are also offered – cast into stainless steel jackets and supplied with a loose, slip-on, mild steel mounting flange to be welded at the required wall thickness. All standard burners in these series are fitted with a direct spark igniter and flame rod. UV scanning (specified at time of order) is an available option with all of the burners. Pilot ignition may be fitted on burners using castable refractory tiles if desired.

Capacities and Specifications

Capacity Air Pressure* Gas Pressure*

Outlet

Flame

Weight

Model No.

Part No.

kW

mbar

mbar

Velocity m/s

Lengthmm

(kg)

GLV 300

2.20.360

348

20

10

50

900

18

GLV 660

2.20.361

765

20

10

50

900

31

GLV1000 2.20.362

1160

20

10

50

900

33

GMV 300 2.20.363

348

30

20

90

1000

19

GMV 660 2.20.364

765

30

20

90

1000

33

GMV 1000 2.20.365

1160

30

20

90

1000

35

GHV 300 2.20.366

348

50

40

150

1100

19

GHV 660 2.20.367

765

50

40

150

1100

33

GHV 1000 2.20.368 35 Note: Minimum required pressure differential across the burner – based on zero chamber pressure 1160 50 40 150 1100

Fives North American Combustion UK, Ltd. Heath Mill Road, Wolverhampton WV5 8BD England Tel +44 (0) 1902 891200 Fax +44 (0) 1902 895552 email: fna.salesUK@fivesgroup.com www.fivesgroup.com