Combustion Catalog | Fives North American

Sheet 3070-1 page 3

Sizing Table, SI Units for High Pressure Inspirator

Table 2 Capacities in Nm 3 /h for 3070 International System of Units Inspirators as High Pressure Air Reducers ( Combustion Blower Alternative)

Low pressure air discharged in Nm 3 /h 69 mbar 103 mbar

designation Outlet size Inspirator

Inlet size Outlet P.

Spud Drill size

34.5 mbar

5.52 bar 138 mbar

Name

Ø mm

Inlet P.

1.38 bar

2.76 bar

4.14 bar

47 44 37 7/64 33 32 29 9/64

2.01 2.18 2.64 2.77 2.87 2.95 3.45 3.58 4.22 4.50 4.57 4.98 5.23 6.05 6.53 6.63 7.67 8.03 8.43

20 25 32 37 44 50 56 68 85

28 35 45 52 63

34 43 55 64 76 86 96 118

40 50 63 74 88

1" NPT 3070-1

3/8 " NPT

1 1/4 " NPT 3070-2

1/2 " NPT

71

100

1 1/2 " NPT 3070-3

78 96

111

1/2 " NPT

136 170 215 232 278 328 362 436 481 538 680 799 1189 1472

19 16 15

120

147 187 201 239 283 314 377 416 467 589 691 1031 1274 1770 2110

2" NPT 3070-4

1/2 " NPT

108

151

116

164 195 232 256 309 340 379 481 564 841 1042 1444 1727

9 5 B

139 164 181 218 241

2 1/2 " NPT 3070-5

3/4 " NPT

3" NPT 3070-6

F

G N O Q

3/4 " NPT

269 340 399 595 736 1019 1218

4" NPT 3070-7

1" NPT

11.1

7/16

11.9 12.7 13.5

15/32

6" NPT 3070-8

1" NPT

2039 2435

1/2

17/32

8" NPT 3070-9

18.3

1 1/2 " NPT

2095

2973

3625

4191

23/32

Note: To find approximate compressed air flow, multiply air capacity by 0.21 Example: for 3070-4-16 compressed air at 12.8 mbar is approximately 151 X 0.21 = 32 Nm 3 /h For ordering information, see page 2.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker