Combustion Catalog | Fives North American

North American 6435 Dual-Fuel Burner Engineering Data

Sheet 6435-2

6435-1

Main Air Pressure, osi

Not Burning Main air, scfh

0.2

1

4

9

16

30

1350

Atom. air, scfh at 30 osi Atom. air, scfh at 8 osi

195

90

Burning Natural Gas Main air, scfh, stoich.

0.2

1

4

9

16

30

65 90

240

545

870

1220

1690

Atom. air, scfh at 8 osi, stoich.

90

90

90

75

50

† Total air, scfh, stoich. Gas flow, stoich., scfh

290

465

770

1100

1430

1870

29

47

77 1.8

110

143 5.6

187

Gas pressure, stoich., osi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.22

0.65

3.25

10.0

2

3

6

8

9

10

1

1

1

1

1

1

0.15

0.4

1.15

2.1

3.5

6.2

Max. %XSAir

‡ Stability and flame supervision

20 20 25

100 100

250 250

400 400

400 400

400 400

Ignition--pilot

Max. %XSFuel

25

25

25

25

0

Burning #2 Oil

0.2

1

4

9

16

30

Main air, scfh, stoich.

85

230 190 555 0.39

545 190

865 185 1180 0.84

1200

1680

§ Atom. air, scfh at 30 osi, stoich.

195 415

180

175

† Total air, scfh, stoich. Oil flow, stoich., gph

870 0.62

1520 1.08 0.35

1990

0.29

1.42

Oil pressure, stoich., psi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.1

0.1

0.1

0.2

0.69

2

2

4

8 2

9 2

11

1

1

1

2

0.08

0.4

1.3

2.4

3.7

6.2

Max. %XSAir ‡ Stability and flame supervision

20 20 25

50 50 25

50 50 25

110 110

200 200

250 250

• Ignition--pilot

Max. %XSFuel

25

25

0

† Total air is main air plus atomizing air plus 135 scfh for pilot air. ‡ Honeywell Ultravision Flame Detector C7027A and Honeywell Flame Supervision Protectorelay RA890G yielded 1.5 micro amps or greater for all above rates. § 30 osi is recommended atomizing air pressure for oil, but all burners will operate on oil with 22 osi atomizing air (at the burner) and 10% or more excess air. • Direct spark ignition on oil is not considered a viable lighting method due to the lack of repeatability. NOTE: Test results above were obtained with pilot air regulated at 2 osi above tile pressure, resulting in constant flow of 135-140 scfh air. Because of the small size of this burner, pilot air must not be run any higher. Velocity: The distance (in inches) from the tile outlet to the point where the tile velocity pressure is 0.1"wc (1259 fpm) is 40" on gas and 48" on oil (firing stoichiometric with 16 osi main air pressure).