Combustion Catalog | Fives North American

Sheet 6435-2, 12-01 Page 2

6435-2

Main Air Pressure, osi

Not Burning Main air, scfh

0.2

1

4

9

16

30

3000

Atom. air, scfh at 30 osi Atom. air, scfh at 8 osi

150

65

Burning Natural Gas Main air, scfh, stoich.

0.2 170

1

4

9

16

30

500

1090

1660

2280

3430

Atom. air, scfh at 8 osi, stoich.

65

65

45

45

30

30

† Total air, scfh, stoich. Gas flow, stoich., scfh

375

705

1270

1850

2450

3600

37 0.1

71

127

185

245 7.97

360 11.55

Gas pressure, stoich., osi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.58

2.02

4.62

6 2

4 2

6 3

6 2

6 2

11 3

0.15

0.6

1.75

4.0

6.7

11.0

Max. %XSAir ‡ Stability and flame supervision

100 100 25+

350 350 25+

400 400 25+

400 400 25+

400 400 25+

200 200

Ignition--pilot

Max. %XSFuel

0

Burning #2 Oil

0.2

1

4

9

16

30

Main air, scfh, stoich.

165 150

430 145 715 0.51

1070

1660

2280

3250

§ Atom. air, scfh at 30 osi, stoich.

145

140

140

120

† Total air, scfh, stoich. Oil flow, stoich., gph

455 0.32

1360 0.96

1940

2560

3510

1.39 0.8

1.83

2.5 2.5

Oil pressure, stoich., psi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.1

0.2

0.4

1.4 10

5

6

5

9 2

10

1.5 0.1

1.5

1.5

2

2.5

0.55

1.75

3.9

6.6

12.3

Max. %XSAir ‡ Stability and flame supervision

25 25

50 50 15+

200 200

300 300

300 300

350 350

• Ignition--pilot

Max. %XSFuel

15+

15+

15+

15+

0

† Total air is main air plus atomizing air plus 140 scfh for pilot air. ‡ Honeywell Ultravision Flame Detector C7027A and Honeywell Flame Supervision Protectorelay RA890G yielded 1.5 micro amps or greater for all above rates. § 30 osi is recommended atomizing air pressure for oil, but all burners will operate on oil with 22 osi atomizing air (at the burner) and 10% or more excess air. • Direct spark ignition on oil is not considered a viable lighting method due to the lack of repeatability.

NOTE: Burner is stable on atomizing air only, but should not be operated below 0.2 osi main air to avoid overheating the tile.

Velocity: The distance (in inches) from the tile outlet to the point where the tile velocity pressure is 0.1"wc (1259 fpm) is 56" on gas and 60" on oil (firing stoichiometric with 16 osi main air pressure).