Combustion Catalog | Fives North American

Sheet 6435-2 Page 4

6435-4

Main Air Pressure, osi

Not Burning Main air, scfh

0.2

1

4

9

16

20

7240

Atom. air, scfh at 30 osi Atom. air, scfh at 8 osi

460 240

Burning Natural Gas Main air, scfh, stoich.

0.2 545 230 905

1

4

9

16

20

1270 230 1630

2830

4350

6050

6900

Atom. air, scfh at 8 osi, stoich.

215

190

160

140

† Total air, scfh, stoich. Gas flow, stoich., scfh

3170

4670

6350

7150

90 0.1

163 0.7

317 2.4

467

635

715

Gas pressure, stoich., osi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

5.2 20

8.7 20

10.7

11 3

18

20

22

3

3

4

4

5

0.1

0.35

1.3

2.8

4.5

5.5

Max. %XSAir ‡ Stability and flame supervision

75 75

300 300

350 350 200 30+

400 400 400 30+

350 350 250 30+

350 350 250

Ignition--pilot

 Ignition--direct spark

Stoich

50

Max. %XSFuel

30+

30+

0

Burning #2 Oil

0.2

1

4

9

16

20

Main air, scfh, stoich.

665 455 1250

1240 440 1810

2750

4310

5850

6590

§ Atom. air, scfh at 30 osi, stoich.

425

415

390

370

† Total air, scfh, stoich. Oil flow, stoich., gph

3305

4855

6370

7090

1.0

1.3 1.0

2.4

3.5

4.6 1.8

5.1 2.1 20

Oil pressure, stoich., psi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.9

1.2

1.5 19

10

10

17

20

3

3

3

4

4

4

0.05

0.4

1.5

3.2

5.6

6.8

Max. %XSAir ‡ Stability and flame supervision

25 25 10

50 50 20

200 200 20+

250 200 20+

300 200

300 200

• Ignition--pilot

Max. %XSFuel

20

0

† Total air is main air plus atomizing air plus 130 scfh for pilot air. ‡ Honeywell Ultravision Flame Detector C7027A and Honeywell Flame Supervision Protectorelay RA890G yielded 1.5 micro amps or greater for all above rates. § 30 osi is recommended atomizing air pressure for oil, but all burners will operate on oil with 22 osi atomizing air (at the burner) and 10% or more excess air.  Electrode setup used was that shown in drawing B4-7249. Cooling air was shut off for ignition and turned back on afterwards. • Direct spark ignition on oil is not considered a viable lighting method due to the lack of repeatability. Velocity: The distance (in inches) from the tile outlet to the point where the tile velocity pressure is 0.1"wc (1259 fpm) is 75" on gas and 85" on oil (firing stoichiometric with 16 osi main air pressure).

Made with FlippingBook flipbook maker