Combustion Catalog | Fives North American

Sheet 6435-2 Page 6

6435-6

Main Air Pressure, osi

Not Burning

0.2

1

4

9

16

20

Main air, scfh

17 500

Atom. air, scfh at 30 osi Atom. air, scfh at 16 osi

560 400

Burning Natural Gas

0.1

1

4

9

16

20

Main air, scfh, stoich.

1000 400 1530

3500

7100 390 7600

11 300

15 200

16 900

Atom. air, scfh at 16 osi, stoich.

400

390

380

360

† Total air, scfh, stoich. Gas flow, stoich., scfh

4030

11 800

15 700

17 400

153

403

760

1 180

1 570

1 740

Gas pressure, stoich., osi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.1

0.7

2.4

5.2 36

9.0

11.2

15

27

24

36

36

4 0

6

7

7

8

8

0.3

1.2

2.15

3.8

5.0

Max. %XSAir ‡ Stability and flame supervision

5 5

300 250

600 250

600 250

600 100

550 100

Ignition--pilot

Max. %XSFuel

30

30

30

0

30%XSA

30%XSA

Burning #2 Oil

0.1

1

4

9

16

20

Main air, scfh, stoich.

1200

3600

7400

11 200

15 000

17 400

§ Atom. air, scfh at 30 osi, stoich.

560

540

540

500

470

480

† Total air, scfh, stoich. Oil flow, stoich., gph

1890

4270

8050

11 800

15 600

18 010

1.4

3.1

5.8

8.5 1.0 36

11.1 2.2 36

12.9

Oil pressure, stoich., psi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

3.5 40

15

24

31

4 0

5

7

7

7

8

0.35

1.1

2.5

4.3

4.5

Max. %XSAir

‡ Flame supervision

25 25 25 30

200 300 250

400 600 500

600 600 500

600 600 600

250 250

Stability

     

• Ignition--pilot

Max. %XSFuel

30

30

30

30

0

† Total air is main air plus atomizing air plus 130 scfh for pilot air. ‡ Honeywell Ultravision Flame Detector C7027A and Honeywell Flame Supervision Protectorelay RA890G yielded 1.5 micro amps or greater for all above rates. § 30 osi is recommended atomizing air pressure for oil, but all burners will operate on oil with 22 osi atomizing air (at the burner) and 10% or more excess air.  Burner will not light. • Direct spark ignition on oil is not considered a viable lighting method due to the lack of repeatability. Velocity: The distance (in inches) from the tile outlet to the point where the tile velocity pressure is 0.1"wc (1259 fpm) is 105" on gas and 105" on oil (firing stoichiometric with 16 osi main air pressure). WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker