Combustion Catalog | Fives North American

Sheet 6435-3 Page 2

6435-2 – 800°F Main Air, Cold Atomizing Air

Main Air Pressure, osi

Burning Natural Gas

0.2

1

4

9

16

26

Main air, scfh, stoich.

200

510

950 1380

1860 2360

Atom. air, scfh at 8 osi, stoich. †Total air, scfh, stoich. Gas flow, stoich., scfh Gas pressure, stoich., osi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich. Max. %XSAir ‡Stability and flame supervision

60

60

60

50

40

20

390

700

1140 1560 114 156

2030

2510

39 0.2

70

203

251 7.7

0.6

1.6

3.0

5.0

6

8 2

10

11

12

14

1.5 0.1

2

2.5 2.5

2.5 4.1

2.5 6.5

0.5

1.3

400 400 400 400

400 400 400 400

400 400

400 400

‡Ignition--pilot

Max. %XSFuel

30

30

30

30

30

30

Burning #2 Oil

0.2

1

4

9

16

26

Main air, scfh, stoich.

220 170 520 0.38

430 180 740 0.53

900 1390 1850 2320

Atom. air, scfh at 30 osi, stoich.

200

210 220

220

†Total air, scfh, stoich. Oil flow, stoich., gph

1230 1730 2200

2670

0.88

1.24 1.57

1.9 1.0

Oil pressure, stoich., psi Flame length, in., stoich. Flame diameter, in., stoich. Tile pressure, osi, stoich.

0.1

0.5

0.7

4 2

8 2

10

11

12

12

2

2.5 2.6

2.5 4.4

2.5 7.2

0.1

0.5

1.4

Max. %XSAir ‡Stability and flame supervision

50 50

50 50

175 175

250 400 250 400

400 400

‡Ignition--pilot

Max. %XSFuel

25

25

25

25

20

5

The external metal temperatures recorded with neutral furnace pressure and in a cold chamber with preheated air were as follows:

Metal temperatue, F

Body

Preheat Air (Main Air temperature, F (near flange) Inlet Flange) Body

Backplate

400 600 800

240 290 305

260 330 470

240 350 450

† Total air is main air plus atomizing air plus 130 scfh for pilot air. ‡ Honeywell Ultravision Flame Detector C7027A and Honeywell Flame Supervision Protectorelay RA890G yielded 1.5 micro amps or greater for all above rates.

Made with FlippingBook flipbook maker