Combustion Catalog | Fives North American

Dimensions 6514 Page 2

6514- /LX (refractory tile)

Burner

wt lb

Dimensions in inches

R 1 

Z  AA  BB CC

DD  323⁄16

designation Q

R

S

T

U

V

W

X

Y

6514-6 6514-7

— — —

53⁄16 61⁄8 73⁄8 8 ½

103⁄8 101⁄8 11 ¼ 123⁄8

19⁄16 19⁄16

37⁄16

19 ½

103⁄8 113⁄8 123⁄8 13 ½

9

4

4

41⁄16 47⁄16

15 16 19 23

5⁄8 5⁄8 5⁄8 5⁄8

8 ¼ 9 ¼

195 225 335 450 795

315⁄16 20½

87⁄8 4¾

41⁄16 47⁄8 611⁄16

343⁄8

6514-8-A 6514-8-B 6514-9 6514-10

113⁄16 45⁄16 113⁄16 45⁄16 313⁄16 63⁄16

22 ¾

10

65⁄16

415⁄16 17¾ 5⁄8

1213⁄16 1213⁄16 1411⁄16

4115⁄16 4813⁄16

13⁄16 15⁄16 19⁄16

24 28

127⁄8 83⁄16

53⁄16 63⁄16

133⁄8 157⁄16

— —

16

137⁄16 115⁄16 87⁄16

57 ½

43⁄8

515⁄16 32½

20 ½

135⁄8 131⁄16 113⁄16 611⁄16 27½ ½

161⁄8

6313⁄16

1035

6514- /LC,L4,L9 (jacketed tile)

All 6514

Dimensions in inches

Burner

wt lb

Recommended Sensitrol ™ oil valve

Recommended

designation AA BB CC

DD

pilot tip 4021-12 4025-0-T 4025-0-T 4025-0-T 4025-2-T 4025-2-T

6514-6 6514-7

16 17

¾ ¾ ¾ ¾

83⁄8 93⁄8

325⁄16 34 ½

215 250 370 495 860

1813-02-C 1813-02-D 1813-02-D 1813-02-D

6514-8-A 6514-8-B 6514-9 6514-10

18 ¾

1215⁄16 421⁄16 1215⁄16 4815⁄16

20

24 ¼ 27 ½

13⁄16 11⁄16

147⁄8 165⁄16

5711⁄16 6313⁄16

1813-01 1813-01

1085

  A square threaded flange is used for sizes -6, -7, -8. SW style (suitable for slip-on or welded connection) inlet may be ordered as a special option. An SW inlet is standard for -9 and -10 burners.

 Opening in furnace shell or outer wall must be ½ " larger than dimension "AA" to allow for mounting plate fillet and draft.

 Blank boss--This may be ordered as a special option with a 1 ½ " tap suitable for 5025-3-1T Oil Pilot, in which case North American will drill out ½ " web of refractory left in tile before shipment, and the burner nose will be positioned so none of its holes are in front of that opening. For -10 size, an appropriate 1 ½ " npt half-coupling will be added as a special option.

 1" fpt for electrode or UV flame detector.

 Pipe nipple and optional (recommended) Sensitrol Oil Valve are not included as part of the burner assembly, and must be ordered separately. Dimensions Z and DD assume a 3⁄8 " close nipple between burner and Sensitrol Oil Valve (6514-6 through -8-B) and a ½ " close nipple between burner and Sensitrol Valve (6514-9 and -10).  Applies when optional SW inlet is specified.

 Flanged connection--a standard Fives square threaded flange is used.

 Flanged connection--a standard ANSI 125 psi threaded flange is used.

 Optional 8773 flex tubing purchased separately from North American.

ANSI or SW flanges: Flat face companion flanges and full face gaskets are supplied with this equipment. Do not use raised face flanges that may damage mating flange.