Dimensions 6514 Page 2
6514- /LX (refractory tile)
Burner
wt lb
Dimensions in inches
R 1
Z AA BB CC
DD 323⁄16
designation Q
R
S
T
U
V
W
X
Y
6514-6 6514-7
— — —
53⁄16 61⁄8 73⁄8 8 ½
103⁄8 101⁄8 11 ¼ 123⁄8
19⁄16 19⁄16
37⁄16
19 ½
103⁄8 113⁄8 123⁄8 13 ½
9
4
4
41⁄16 47⁄16
15 16 19 23
5⁄8 5⁄8 5⁄8 5⁄8
8 ¼ 9 ¼
195 225 335 450 795
315⁄16 20½
87⁄8 4¾
41⁄16 47⁄8 611⁄16
343⁄8
6514-8-A 6514-8-B 6514-9 6514-10
113⁄16 45⁄16 113⁄16 45⁄16 313⁄16 63⁄16
22 ¾
10
65⁄16
415⁄16 17¾ 5⁄8
1213⁄16 1213⁄16 1411⁄16
4115⁄16 4813⁄16
13⁄16 15⁄16 19⁄16
24 28
127⁄8 83⁄16
53⁄16 63⁄16
133⁄8 157⁄16
— —
16
137⁄16 115⁄16 87⁄16
57 ½
43⁄8
515⁄16 32½
20 ½
135⁄8 131⁄16 113⁄16 611⁄16 27½ ½
161⁄8
6313⁄16
1035
6514- /LC,L4,L9 (jacketed tile)
All 6514
Dimensions in inches
Burner
wt lb
Recommended Sensitrol ™ oil valve
Recommended
designation AA BB CC
DD
pilot tip 4021-12 4025-0-T 4025-0-T 4025-0-T 4025-2-T 4025-2-T
6514-6 6514-7
16 17
¾ ¾ ¾ ¾
83⁄8 93⁄8
325⁄16 34 ½
215 250 370 495 860
1813-02-C 1813-02-D 1813-02-D 1813-02-D
6514-8-A 6514-8-B 6514-9 6514-10
18 ¾
1215⁄16 421⁄16 1215⁄16 4815⁄16
20
24 ¼ 27 ½
13⁄16 11⁄16
147⁄8 165⁄16
5711⁄16 6313⁄16
1813-01 1813-01
1085
A square threaded flange is used for sizes -6, -7, -8. SW style (suitable for slip-on or welded connection) inlet may be ordered as a special option. An SW inlet is standard for -9 and -10 burners.
Opening in furnace shell or outer wall must be ½ " larger than dimension "AA" to allow for mounting plate fillet and draft.
Blank boss--This may be ordered as a special option with a 1 ½ " tap suitable for 5025-3-1T Oil Pilot, in which case North American will drill out ½ " web of refractory left in tile before shipment, and the burner nose will be positioned so none of its holes are in front of that opening. For -10 size, an appropriate 1 ½ " npt half-coupling will be added as a special option.
1" fpt for electrode or UV flame detector.
Pipe nipple and optional (recommended) Sensitrol Oil Valve are not included as part of the burner assembly, and must be ordered separately. Dimensions Z and DD assume a 3⁄8 " close nipple between burner and Sensitrol Oil Valve (6514-6 through -8-B) and a ½ " close nipple between burner and Sensitrol Valve (6514-9 and -10). Applies when optional SW inlet is specified.
Flanged connection--a standard Fives square threaded flange is used.
Flanged connection--a standard ANSI 125 psi threaded flange is used.
Optional 8773 flex tubing purchased separately from North American.
ANSI or SW flanges: Flat face companion flanges and full face gaskets are supplied with this equipment. Do not use raised face flanges that may damage mating flange.