6435-6 with Cold Main Air, Cold Atomizing Air
Main Air Pressure osi/"w.c./mbar
Not Burning Main Air Flow scfh (Nm 3 /h)
17 500 (468)
Atom. air, scfh (Nm 3 /h) @ 30 osi/51.9"w.c./129 mbar Atom. air, scfh (Nm 3 /h) @ 8 osi/13.8"w.c./34.5 mbar
560 (15.0) 400 (10.7)
Burning Natural Gas
osi
0.2 0.3 0.9
1
4
9
16
20
"w.c. mbar
1.7
6.9 17.2
15.6
27.7
34.6
4.3
39
69
86
Main Air Flow, stoich. ratio
scfh
1000 (26.7)
3500 (93.6)
7100 (190) 390 (10.4) 4600 (203)
11 300
15 200
16 900
(Nm 3 /h)
(302)
(406)
(452)
Atom. Air Flow @ 8 osi/35.5 mbar stoich. ratio
scfh
400
400
390
380
360
(Nm 3 /h)
(10.7) 1530 (40.9)
(10.7) 4030 (108)
(10.4)
(10.2)
(9.62) 17 400 (465) 1740 (46.5)
† Total Air Flow, stoich, ratio
scfh
11 800
15 700 (420) 1570 (42.0)
(Nm 3 /h)
(315) 1180 (31.5)
Gas Flow stoich. ratio
scfh
153
403
460
(Nm 3 /h)
(4.09)
(10.8)
(20.3)
Gas pressure stoich. ratio Tile pressure stoich. ratio
"w.c. (mbar) "w.c. (mbar)
0.17 (0.4)
1.2 (3.0) 0.5 (1.3)
4.2 (10.3) 9.0 (22.4) 15.6 (38.8) 19.4 (48.3)
0 (0)
2.1 (5.2)
3.7 (9.3) 6.6 (16.4)
8.7 (21.5)
‡ Max. % XSAir Stablility UV Flame supervision
5 5
300 250
600 250
600 250
600 100
550 100
Max. % XSAir Ignition--pilot
Max. % XSFuel
30
30
30
0
30% XSA 36 (914)
30% XSA 36 (914) 8.0 (203)
Flame length stoich. ratio Flame diameter stoich. ratio
inch (mm) inch (mm)
15 (381) 4.0 (102)
27 (686) 6.0 (152)
24 (610) 7.0 (178)
36 (914)
7.0 (178) 8.0 (203)
Burning #2 Oil
Main Air Flow, stoich. ratio
scfh
1200 (32.1)
3600 (96.2)
7400 (198)
11 200
15 000
17 400
(Nm 3 /h)
(299)
(401)
(465)
§ Atom. Air Flow @ 30 osi/129 mbar stoich. ratio
scfh
560
540
540
500
470
480
(Nm 3 /h)
(15.0) 1890 (50.5)
(14.4) 4270
(14.4) 8050
(13.4)
(12.6)
(12.8)
† Total Air Flow, stoich, ratio
scfh
11 800
15 600
18 010
(Nm 3 /h)
(114)
(215)
(315)
(417)
(481)
Oil Flow stoich. ratio
gph (lph)
1.4
3.1
5.8
8.5
11.1
12.9
(5.3)
(11.7)
(22.0)
(32.0)
(42.0)
(48.8)
Oil pressure stoich. ratio Tile pressure stoich. ratio
psi (mbar) "w.c. (mbar)
0.1 (6.9)
0.1 (6.9) 0.6 (1.5)
0.1 (6.9)
0.2 (3.8) 0.35 (24)
0.69 (48) 7.8 (19.4)
0 (0)
1.9 (4.7) 4.3 (10.8) 7.4 (18.5)
‡ Max. % XSAir UV Flame supervision
25 25 25 30
200 300 250
400 600 500
600 600 500
600 600 600
250 250
Max. % XSAir Stability
0
• Max.% XSAir gnition--pilot
Max. % XSFuel
30
30
30
30
Flame Length stoich. ratio Flame diameter stoich. ratio
inch (mm) inch (mm)
15 (381) 4 (102)
24 (610)
31 (787)
36 (914)
36 (914)
40 (1016)
5 (127)
7 (178)
7 (178)
7 (178)
8 (203)
† Total air is main air plus atomizing air plus 130 scfh for pilot air. ‡ Honeywell Ultravision Flame Detector C7027A and Honeywell Flame Supervision ProtectoRelay RA890G yielded 1.5 micro amps or greater for all above rates. § 30 osi is recommended atomizing air pressure for oil, but all burners will operate on oil with 22 osi atomizing air (at the burner) and 10% or more excess air. Burner will not light. • Direct spark ignition on oil is not considered a viable lighting method due to the lack of repeatability. Velocity: The distance (in inches) from the tile outlet to the point where the tile velocity pressure is 0.1"w.c. (1259 fpm) is 105" on gas and 105" on oil (firing stoichiometric with 16 osi main air pressure). Bulletin 6435 Page 14