Bulletin 6570 Page 4
DIMENSIONS in inches
"T" Connection, F Style
L
E
C -NPT–Oil conn.
Recommended Sensitrol™ Oil Valve
P
F
2 13⁄16
J
B -NPT Gas
A –pipe size
2 ½ NPT Atomizing Air
M
3 ¼
H
D
N
Q Flange Thickness
Main Air F Style ANSI Class 150 (ASA 125 lb) Flange Pattern
"Y" Connection, SW Style
¾ NPT–Pilot UV
¾ NPT–pilot mixture 1 NPT–Main Flame Obs. (or UV)
R240-2802 Spark Electrode
E
L
(Same as above)
45°
1 NPT UV with 1 ¾ hex bushing
K
A –pipe size
OPTIONS 45° or 90° main air connection. Flanged or slip-on main air connection. When ordering, specify choice of options as follows: (P) for spark ignited pilot (Y) for 45° air connection (T) for 90° air connection (F) for flanged air connection (SW) slip-on or welding air connection Example: 6570-12-PTF Burner complete 1813-01 Sensitrol Oil Valve 4570 HiVAM ™ s for gas only have the same dimensions (except for "N" and "C", which do not apply) and practically the same weights as 6570 HiVAMs since the gas burners also have an "atomizing air" connection for greater flame stability. Main Air SW Style Slip-Fit or Welding Conn. G DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSITON, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
Recommended
Approx. net weight
dimensions in inches
Burner
Sensitrol™ Oil Valve 1813-02-D
designation A B C
D
E
F
G
H
J
K
L
M
N P Q
lb
15 13⁄16 23 7⁄8
4 1⁄8
8 5⁄8
125
6570-9 6570-12
8 2 ½ 3⁄8
16 1⁄16 19 13⁄16
15 13⁄16 21 5⁄16
3 ¾ 29 15⁄16 4 ¾ 42 13⁄32
7 7⁄8
8 11 5⁄16
3⁄8 ½
12 3
8
12 14 27⁄32 23 13⁄16 34 5⁄8 5 1⁄16 11 ¾
1813-01
200
½
Optional (recommended) Sensitrol Oil Valve is not included as part of the burner assembly, and must be ordered separately.
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com