Dimensions | HiRAM® Burners
ØV
Y - no. of holes ØX
½ "
DIMENSIONS inches
ØA
ØC
Burner
input pipe sizes
designation A
B
C
D
ØG
6575-8-B
6 8
2 ½ 2 ½
2 ½ 2 ½ 2 ½ 2 ½ 2 ½
3⁄8 3⁄8 ½ ½ ½
6575-9
6575-10-A 6575-10-B
10 10 12
3 3 3
ØB
ØW
Z°
Z°
6575-12
T
P
S R
N
M
Q
Ø.75 X 12 holes equally spaced
3⁄8 "
¾ fpt pilot & UV
ØU
H
J
ØE
ØF
K
ØD
L
1813 Sensitrol™ Oil Valve (optional--not supplied with burner)
15°
15°
¼ fpt pressure tap shipped with pipe plugs in place
8790-0 Obs. Port 2 furnished
1⁄8 fpt pressure tap shipped with pipe plugs in place
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
Burner
dimensions in inches
H *
designation E F G
J
K
L M
N P
Q R
S
T
U V W
X
Y
Z
6575-8-B
4 5⁄8 14 18 5 5⁄16 14 18
7 ½ 7 ½
3 ¾ 3 ¾ 4 ¾ 4 ¾ 4 ¾
2 13⁄16 2 13⁄16 2 13⁄16 2 13⁄16 2 13⁄16
1 1⁄8 1 1⁄8
9 16 5⁄8 9 16 5⁄8
9 ½ 9 ½
6 5⁄8 6 5⁄8 7 1⁄8 7 1⁄8 7 1⁄8
5 ¼ 5 ¼ 5 ¼ 5 ¼ 5 ¼
2 9⁄16 2 9⁄16 3 1⁄16 3 1⁄16 3 1⁄16
49 9⁄16 49 9⁄16
16
9 7.88 0.56 8 22 ½
6575-9
16 11 10.0 0.56 8 22 ½
6575-10-A 6575-10-B
6 ¼ 18 22 10 ½ 6 ½ 18 22 10 ½ 7 18 22 10 ½
1 5⁄8 12 20 5⁄8 11 1⁄16 1 5⁄8 12 20 5⁄8 11 1⁄16 1 5⁄8 12 20 5⁄8 11 1⁄16
59 1⁄8 59 1⁄8 59 1⁄8
20 14 12.25 0.75 12 20 14 12.25 0.75 12 20 16 14.25 0.75 12
15 15 15
6575-12
* SW style inlet (optional--see Parts List, 6575-2) will add 4 3⁄8 " to dimension "H" shown.
HiRAM ® ORDERING INFORMATION
Main Air
4
Optional Sensitrol
Pilot/UV * position designators are
2 3 1
4
Burner
recommended net weight
designation
valve
pilot set 4011-12 4011-12 4011-12 4011-12 4011-12
lb
a
a
Gas conn. position designators are
c d b
1813-02-C 1813-02-D
215 215
6575-8-B
E
6575-9
Atomizing air connection position designators are
E G H F
6575-10-A 6575-10-B
1813-01 1813-01 1813-01
300 300 300
* Dual Pilot/UV positions are available upon request.
view from outside furnace
6575-12
NOTE: Position #4 may not be suitable for some flame scanners due to interference with the main air connection.
To order, specify: 6575-(code)-(A or B if applicable) Burner complete (specify Arrangement Designator--see sketch above). List 1813 Sensitrol ™ Oil Valve as a separate line item. Example: (1) 6575-9 Burner complete, Arrangement 4aE (1) 4011-12 ¾ " Threaded Spark Pilot Set (1) 1813-02-D Sensitrol Oil Valve
Arrangement Designators are specified relative to the main air connection at 12 o'clock and should be listed for pilot/UV, gas connection, and atomizing air connection in that order. Good practice dictates that the pilot/UV NOT be on the bottom of the burner.
Bulletin 6575 Page 4
Made with FlippingBook flipbook maker