Combustion Catalog | Fives North American

Capacities | 6570 HiVAM ™

osi

0.2 0.3 0.9

1

4

9

16

16

Main air pressure drop across burner

"w.c. mbar

1.7

6.9 17.2

15.6

27.7

27.7

6570-9

4.3

39

69

69

scfh

9000

13 500

39 300

59 000

80 000 96 000

Main Air Flow (Gas firing)

(Nm 3 /h)

(241)

(361)

(1050)

(1577)

(2138)

(2566)

scfh

10 300

13 500

42 500

63 500

83 000 96 000

Atomizing Air Flow (Oil firing)

(Nm 3 /h) (Nm 3 /h) (Nm 3 /h)

(275) 2380 3100

(361) 2380 3100 1250 (33.4)

(1136) 2245 3100 2950 (78.9)

(1697) 2245 2725 4260

(2219) 2100 2650 5630 (150)

(2566) 2600

Atomizing Air Flow (Gas firing)  Atomizing Air Flow (Oil firing) 

3550

scfh

950

0 0

Natural Gas Flow @ 50% excess air

(Nm 3 /h)

(25.4)

(114)

not burning use for sizing blowers

Gas pres. @ 50% excess air

"w.c. (mbar)

0

0.7 (1.7)

3.1 (7.8) 6.6 (16.4) 12.8 (31.9)

Max. % XSA (Gas), UV flame signal  Max. % XSA (Oil), UV flame signal  Flame Length (Gas) @ 50% XSAir Flame Diameter (Gas) @ 50% XSAir Flame Length (Oil) @ 50% XSAir Flame Diameter (Oil) @ 50% XSAir

600

1000

1200 1200

1200 1200

1000

75

200

850

feet (m) feet (m) feet (m) feet (m)

3.0 (0.9) 1.0 (0.3) 3.0 (0.9) 1.0 (0.3)

3.5 (1.1) 1.0 (0.3) 4.0 (1.2) 1.0 (0.3)

4.0 (1.2) 1.0 (0.3)

4.0 (1.2) 1.0 (0.3) 5.5 (1.7) 1.0 (0.3)

3.5 (1.1) 1.0 (0.3) 5.5 (1.7) 1.0 (0.3)

5.0

1.0 (0.3)

osi

0.2 0.3 0.9

1

4

9

16

16

Main air pressure drop across burner

"w.c. mbar

1.7

6.9 17.2

15.6

27.7

27.7

6570-12

4.3

39

69

69

scfh

19 300

43 100

82 500 (2205) 87 500 (2339)

122 500

170 000 185 000

Main Air Flow (Gas firing)

(Nm 3 /h)

(516)

(1152)

(3274)

(4544)

(4945)

scfh

20 400

45 600

127 000 (3395) 3260 4710 8430 (225) 1.7 (4.3)

169 000 185 000

Atomizing Air Flow (Oil firing)

(Nm 3 /h) (Nm 3 /h) (Nm 3 /h)

(545) 3400 5250 1590 (45.5)

(1219) 3400 5160 3170 (84.7)

(4517) 3120 4520 11 600

(4945) 3400 5660

Atomizing Air Flow (Gas firing)  Atomizing Air Flow (Oil firing) 

3260 4900 5790 (155)

scfh

0 0

Natural Gas Flow @ 50% excess air

(Nm 3 /h)

(310)

Gas pres. @ 50% excess air

"w.c. (mbar)

0

0.35 (0.9)

0.7 (1.7)

2.6 (6.5)

not burning use for sizing blowers

Max. % XSA (Gas), UV flame signal  Max. % XSA (Oil), UV flame signal  Flame Length (Gas) @ 50% XSAir Flame Diameter (Gas) @ 50% XSAir Flame Length (Oil) @ 50% XSAir Flame Diameter (Oil) @ 50% XSAir

700

1000

1100 650

1300

1500 1300

10 

125

850

feet (m) feet (m) feet (m) feet (m)

5.0 (1.7) 0.8 (0.2)

6.5 (2.0) 1.0 (0.3) 6.0 (1.8) 1.5 (0.5)

7.0 (2.1)

7.5 (2.3)

8 (2.4)

1.2 (0.37) 1.3 (0.4)

1.3 (0.4)

— —

9.5 (2.9) 10.0 (3.0) 10.5 (3.2)

1.5 (0.5) 2.0 (0.6)

2.0 (0.6)

Notes:  Atomizing Air pressure (Gas firing) = 24"w.c./60 mbar/14 osi  Atomizing Air pressure (Gas firing) = 17"w.c./43 mbar/10 osi  Atomizing Air pressure (Oil firing) = 36"w.c./86mbar/20 osi  Maximum Excess Air Precentage with flame supervision and without pilot  0.5 osi/.9"w.c./2.2 mbar is the lowest air pressure the 6570-12 burner will run with 50% excess air with oil 16 osi air is maximum firing rate.

Bulletin 6570 Page 3

Made with FlippingBook flipbook maker