Combustion Catalog | Fives North American

Dimensions | 6796 Magna-Flame ™

Bulletin 6796 page 4

Dimensions in Inches and Degrees

Burner Designation A B C

F G° H° I 

D

E

J

K

L

M

N

O

P Q

R

6796-12-46 12 4 0.75 24.25 26 16 11.25 22.5 18 14 14.75 15 14.56 53.63 1.00 17 12 12.25 15 30 6796-14-46 14 6 0.75 25.25 27 16 11.25 22.5 20 14.5 14.75 18 15.75 57.88 1.13 18.75 12 13.88 15 30 6796-16-46 16 6 0.75 27 28.75 20 9 18 22 15.5 14.81 19 17.88 61.75 1.13 21.25 16 15.88 11.25 22.5 6796-18-46 18 6 0.75 29 30.75 20 9 18 24 16.5 14.81 19.5 18.25 62.38 1.25 22.75 16 17.88 11.25 22.5 6796-20-46 20 8 0.88 31 32.75 20 9 18 26 18.5 14 20 20.75 66.63 1.25 25 20 19.88 9 18 6796-22-46 22 8 0.88 33.5 35.25 20 9 18 28 19.5 14 21 21.88 70.50 1.25 26 20 21.88 9 18 6796-24-46 24 8 0.88 35.5 37.75 24 7.5 15 30 20.5 14 22 22.88 72.13 1.38 29.5 20 23.88 9 18

Burner Designation 6796-12-46 6796-14-46

Weight lbs.

Atomizer Designation

Pilot Assy. Designation

U

V W

X° Y° Z AA BB

CC DD 1.5 1.00

EE

FF GG HH

II

19.0 0.75 7.50 22.5 45 8 9 12.5

3.06 17.12 ½ ¾ 94.00 5646-1-110 4014-2-T

430

2.50 17.12 ½ ¾ 94.25 5646-2-150 4014-3-AT 485

21.0 0.88 9.50 22.5 45 8 11 14.75 2.0 1.25

6796-16-46 23.5 0.88 9.50 22.5 45 8 11

17

2.0 1.25

2.88 17.31 ¾ 2.88 17.12 ¾ 2.88 18.31 ¾ 2.88 20.06 ¾ 2.88 19.69 ¾

2 100.75 5646-2-195 4014-3-AT 585 2 102.75 5646-3-250 4014-3-AT 625 2 111.50 5646-3-320 4014-3-BT 730 2 115.25 5646-3-380 4014-3-BT 820 2 119.75 5646-3-450 4014-3-BT 880

6796-18-46 25.0 0.88 9.50 22.5 45 8 11 19.25 2.0 1.50 6796-20-46 27.5 0.88 11.75 22.5 45 8 13.5 21.5 2.0 1.50

6796-22-46 29.5 0.88 11.75 22.5 45 8 13.5 24 6796-24-46 32.0 0.88 11.75 22.5 45 8 13.5 26

2.0 1.50 2.0 1.50

 Furnace opening should be ½" larger than dimension I for sizes -12 through -16 and ¾" larger than dimension I for sizes -18 through -24.  Flat face companion ANSI flange available upon request.  For tiles longer than 15" consult North American.

main air conn.

Pilot position designators ‡ are

Arrangement Designators are specified relative to the main air connection at 12 o'clock and should be listed for pilot, gas, and flame supervision in that order . Atomizer connections need not be specified because they can be rotated in the field.

Gas connection position designators are

Flame supervision designators ‡ are (must be 90° clockwise of pilot).

view from outside furnace

ORDER MUST SPECIFY: (1) Burner designation (such as 6796-16-46): (2) Arrangement designation for pilot, gas and flame safety positions in that order such as: 6796-16-46, arrangement 1½ d 2½ (for the arrangement shown above). ‡Good practice dictates that neither pilot nor flame detector be below the centerline of a horizontally-mounted burner.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.