North American Dual-Fuel ™ Hot Spot Burners Sheet 6841 Dual-Fuel ™ Hot Spot Burners produce short, intense, concentrated flames on gas or distillate oil. Two sizes are available -- 6841-7, which uses 20 osi atomizing air, and 6841-8-B25, which uses 15 psi compressed air for atomization. Excellent turndown characteristics of the 6841-8-B25 permits its use over the capacity range normally served by -8-A and -8-B burners. Use of atomizing air during gas operation permits equal capacity on gas or oil. If reduced gas capacity is acceptable for the 6841-8-B25, compressed air can be reduced to 1 psig (minimum to prevent atomizer overheating). The 6841-7 is stable in a cold, tight chamber. Do not run it rich on oil.

6841-7 Burners have 13 ½ " square by 9" (nominal) long tiles. 6841-8-B25 Burners have 24" diameter grooved tiles. Tiles are of refractory material suitable for 3000°F tile temperature. Tile cover plates are heat-resisting cast iron. Burner internals that see flame are alloy.

Required gas pressure at the burner connection is 3 osi for 6841-7 and 1.5 osi for 6841-8-B25.

Pilots, Flame Supervision. A 4011-12 pilot set is recommended for individual burner ignition. When multiple burners share a single pilot pre-mix header, a 4021-12 pilot tip per burner with an appropriately sized air/gas mixer is recommended. Pilot Tips use 6"wc mixture pressure. Flame rods or UV detectors work satisfactorily with pilot and main gas flames. For monitoring oil fires, only UV is satisfactory--flame rods tend to collect carbon. For satisfactory operation, UV detectors must be purged with air. Flame detectors must be installed clockwise of pilot as viewed from rear of burner. Total Capacities. Gas capacity is based on 0.6 sp gr, 1000 Btu/ft 3 gas, using main and full atomizing air. Oil capacity is based on #2 oil at 140 000 Btu/gallon.

16 osi main air pressure drop acrosss burner

12 osi main air pressure drop across burner

Burner designation

Air, scfh 22 100 57 600

Gas, scfh

Oil, gph

Air, scfh Gas, scfh

Oil, gph

6841-7

2210 5760

15.8 41.1

25 200 66 500

2520 6650

18.0 47.5

6841-8-B25

Main and Atomizing Air Capacities in scfh

main air pressure drop across burner, osi

Burner

Atomizing

0.5

1

5

6

8

12

16

Air, scfh

designation

0.1

1860 6750

4 160 11 500

5 900 16 500

13 100 36 900

14 400 40 400

16 600

20 400

23 500 66 000

1700 at 20 osi 420 at 15 psi

6841-7

6841-8-B25

46 700 57 200

Metric Conversions

1 osi = 43.94 mm H 2 O = 0.004 39 kg/cm 2

1"wc

= 25.40 mm H = 8.899 kcal/m 3 2 O

1Btu/ft 3

1 psi = 0.0703 kg/cm 2

1" C

= 25.40 mm = 5⁄9 (F – 32)

1 Btu/gal = 0.666 kcal/L

= 0.028 26 sm 3 /h = 0.026 86 nm 3 /h

1 scfh 1gph

1 lb = 0.4536 kg

= 0.001 05 L/s

Excess Air

main air pressure drop across burner, osi

Max % Excess Air

0.1

1

4

8

12

16

6841-7, Gas 

– –

250 150 700 550

500 300 120 1030

400 450

375 500 100

350 575 160

6841-7, Oil

6841-8-B25, Gas  6841-8-B25, Oil

160 140

90

1050

1300

1500

  With 150 scfh atomizing air at 1 psi.

  Without atomizing air.

Flame Length

main air pressure drop across burner, osi

Flame Length, inches

1

4

8

12

16

36 27 24 24

40 27 30 36

50

– –

40 22 48 48

6841-7, Gas 6841-7, Oil

16

6841-8-B25, Gas 6841-8-B25, Oil Flame dia., inches 6841-7, Gas

36-48 36-48

36

36-48

24 18

30

48

– –

24

6841-7, Oil

18

14

15