Combustion Catalog | Fives North American

Features | Oil Burners

Bulletin 5422 Page 3

CONSTRUCTION FEATURES

Air inlets can be rotated in 90° increments, but air pipes should be brought in from top or side to prevent oil dripping into them.

Mounting plates are cast iron. Standard tiles are 9" long.† In furnace walls thicker than the tile length, tunnel beyond end of tile should be flared at least 30° included angle, starting at the tile OD. Jacketed Tiles. 5422- -LC Burners have a carbon steel jacket around the tile for furnace walls with no refractory to support the tiles--maximum combustion chamber temperature: 800°F. For higher temperatures, specify -L4 for 304 or -L9 for 309 SST jackets.

An observation port is furnished with all burners.

The 5422 oil atomizer can be easily withdrawn to allow for inspection and/or cleaning of the oil nozzle.

CLEARANCE DIMENSIONS, inches (for details, see Dimensions 5422)

Optional Tile Jacket

3⁄8 NPT Oil Inlet

C ‡ sq.

D

A –NPT Combustion Air Inlet B -NPT Atomizing Air

9"

E

F sq.

Approx. flame lengths with 16 osi Main Air (in open furnace)

Burner

designation

A

B

C ‡

D

E

F

5422-2 5422-3 5422-4 5422-5 5422-6

1 ¼ 1 ½

8 ½ 8 ½ 8 ½ 8 ½ 8 ½

5 5 5 5 5 7 7 7

10 11⁄16 10 11⁄16 10 11⁄16 10 11⁄16 10 11⁄16

12 12 12 12 12

2' 2'

¾ ¾ ¾

2

2 ½ ' 2 ½ '

2 ½

1 1

3 4 4 6

4' 6' 6' 6'

1 ¼ 1 ¼

10 10 10

13 5⁄8 13 5⁄8 13 5⁄8

13 ½ 13 ½ 13 ½

5422-7-A 5422-7-B 5422-8-A

2

† See Dimensions 6422 for ceramic fiber wall installation recommendations. ‡ 5422- -L_ metal jackets add about 1" to tile OD--see Dimensions 5422.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com