Dimensions | 5514 Oil Burners
Bulletin 5514 Page 4
Optional Tile Jacket
CLEARANCE DIMENSIONS (for details, see Dimensions 5514)
C -NPT Oil Inlet
Burner
Dimensions in inches
Wt . lbs. 190 215 320 410 735
G dia.
designation A B C D
E
F
G
H
D dia.
15 10 3⁄8 16 11 3⁄8 17 ¾ 12 3⁄8 19 13 ½
5514-6 5514-7
3 1 ½
19 ½
15 1⁄16
9
3⁄8 3⁄8
H dia.
Burner Nose
4 2
20 ½ 16 7⁄8
8 7⁄8
5514-8-A 5514-8-B 5514-9 5514-10
6 2 ½ 3⁄8
22 ¾
22 3⁄8 10 23 ¼ 12 7⁄8
B -NPT Atomizing Air
6 3 8 4 10 6
24 28
3⁄8 ½ ½
29 15⁄16 13 7⁄16 23 16
32 ½ 33 ¾ 13 5⁄8
27 ½ 20 ½ 950
A –NPT or SW Combustion Air Inlet
E
F
† SW connection standard for -9 and -10 only.
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
ORDERING INFORMATION
5514 -
_ _ _
/
_ _
/
_ _ _ _
Product Size Connection 6 ................. 3" 7.................. 4" 8-A ........... 6" 8-B ............ 6" 9 ................. 8" 10 ...............10"
Tile BO.... burner only LX..... refractory tile (no jacket) LC ..... steel tile jacket L4..... 304 stainless jacket L9..... 309 stainless jacket
Burner Nose
Capacity
Material
1.0......main air capacity 1.1 .......1.1 x main air capacity 1.2 ......1.2 x main air capacity 1.3 ......1.3 x main air capacity
H ....cast iron
A ....alloy
Example 1 Example 2 Example 3
5514-8-A/LC/1.2A Fireall oil burner complete with carbon steel jacketed tile and 1.2 capacity alloy nose
5514-6/BO/1.0H Fireall oil burner only with standard capacity iron nose
5514-9/LX/1.2H Fireall oil burner complete with refractory tile and 1.2 capacity iron nose
Note: See Supplement 6514-6 for cross referencing old product numbers.
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com
Made with FlippingBook flipbook maker