Combustion Catalog | Fives North American

Order 5010 page 2

MOUNTING ADAPTER

Y

Customer Specifies:

Y = Mounting overall length (Minimum length is 1" to allow for removal of flange bolts.) X = Angle (vertical = 0 degrees)

X

EXAMPLE ORDER DESCRIPTIONS

Item Quantity

Part Number

Description

010 020 030 040 050 060 070

1 1

5010-J3-XX 4-21138-1 5010-J3-XX 4-21138-1 4-20762-2 4-20534-1 4-21030-2

Oxygen gas burner: V = 0.625", M = Standard, capacity = 2.0 million Btu/hr

Balancing oxygen orifice, bore = 0.953" ( W )

2

Oxygen gas burner complete with welded flange: V = 0.750" W = 0.5", M = standard, Z = 10", capacity = 3.0 million Btu/hr

1

Balancing oxygen orifice, bore = 1.172" ( W )

2

Refractory tile for 5010-J3

1 1

Hanger for 5010-J3

Mounting adapter for 5010-J3; Y = 5", X = 15 degrees

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker