Combustion Catalog | Fives North American

Product Overview | J/L Oxygen Burner

The 5013G produces exceptionally low NOx emissions. It is a combination of a special 5010N-J3 burner and a special 5030- L lance. The 5013G packages these two together to simplify operation, mounting, piping, and installation of the resulting low NOx oxygen burner. OPERATION 40% of the theoretical oxygen is supplied to the burner while the remaining 60% oxygen is supplied to the lance. The result is a luminous flame with delayed mixing of fuel and oxygen for exceptionally low NOx production.

FLAME IGNITION and SUPERVISION The burner has a rear connection that can accept a UV scanner. Contact North American for specific application information. If a flame supervision system is not used, the burner should only be operated when the chamber temperature has been verified to be above 1400°F. The 5013G does not have a pilot or spark ignition system. APPLICATIONS Glass melters, steel reheat furnaces, aluminum melters, and other high temperature furnaces can benefit from the 5013G's high quality heating and exceptionally low NOx. ORDERING Specify oxygen and natural gas flows in scfh. The 5013G burners' orifices are custom-sized to order.

The fuel and oxygen tubes can be easily removed from the back of the burner for inspection.

CAPACITIES

"J" Burner

"L" Lance

O 2

Natural Gas Natural Gas

O 2

O 2

Total O 2

Flame length Flame diameter

scfh

scfh

osig

scfh

osig

scfh

ft

ft (approximate)

1600 2400 3200 4000 4800

2000 3000 4000 5000 6000

4.0 8.0

2400 3600 4800 6000 7200

4.8 10.4 17.6 25.6 36.8

4000 6000 8000 10000 12000

6 8

3 4 5 5 6

14.0 21.0 29.0

10

11.5

13

DIMENSIONS

25 7⁄16 "

10 1⁄8 "

15"

12

9

9

6 9⁄16 "

8

13

2

5

1

16 6

3

3 ½ "

14

15

4"

1" N. gas inlet (5010-J3 burner)

15"

7 10

4"

2 ½ " Oxygen inlet (5030L Lance)

4

9

11

5

6 1⁄16 "

12"

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.