Combustion Catalog | Fives North American

Bulletin 5020-R4 Page 3

DIMENSIONS inches

BURNER WITH SQUARE TILE

5⁄8 "

12"

Oxygen 2" mpt

12" sq

14” sq

6 ¾ "

Gas 2” fpt

26"

BURNER WITH ROUND TILE

22 ½ "

5⁄8 "

12"

(12) ¾ " holes 20 ½ " B.C.

Oxygen 2" mpt

16" dia.

6 3 /

4 "

Gas 2" fpt

26"

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.

Ordering: Specify capacity in million Btu/h HHV, Tile shape (round or square), and nozzle number. Example: 5020-R4-XX Burner complete, capacity 10 million Btu/hr, round tile, and #2 nozzle. Spark Igniter: A4-18032 Three openings (1/4 NPT) can be used for UV detector, ignition electrode, and observation port.

WARNING: All equipment and pipe used with oxygen must be made of suitable materials and properly cleaned for oxygen service. Operating personnel should be trained in oxygen safety procedures. Failure to do so could result in accidental injury or death. Contact your oxygen supplier and Fives North American Combustion, Inc. for information. WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com