Combustion Catalog | Fives North American

Dimensions | Flame Detector Adapters

Bulletin 8832 Page 10

Sealing Window

Cooling Air Connector R916-2322-S

4-8035-3 Adapter

Sealing Window 4-40395-1

2.13

1.75

Setscrew

Gaskets

Setscrew

Gaskets 2X 4-40386-1

8833-R 8833-R with 1" NPT detectcor connection = 5.00" long 8833-R-0 with ¾ " NPT detector connection = 6.38" long 8833-R-01 with ½ " NPT detector connection = 6.38" long

8839-R 4.50" long Shown with 45UV5 UV Scanner

Sealing Window

Sealing Window

4-7933-2 Adapter

4-7933-2 Adapter

1.75

1.75

Gaskets

Setscrew

Gaskets

Setscrew

8836-R

8836-R

4.50" long Shown with C7027A UV Scanner

4.50" long Shown with UV7A4 UV Scanner

Sealing Window

Sealing Window

R590-1250-S Coupling

4-8316-2 Adapter

1.75

1.75

Gaskets

Setscrew

Gaskets

Setscrew

8831-R 4.50 " long Shown with UV-2 UV Scanner

8834-R 5.00" long Shown with 8790-0 Observation Port

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237

Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com

Made with FlippingBook flipbook maker