Preset # change (Not available on RUN) Data : 1 - 15 for preset #1 - 15
4004
16 for Multi sequence A 17 for Multi sequence B
Forward / Loosening ( F=0, L=1 ) Output test only ( 0 : off, 1 : on) ( MSB=OUT 8, LSB=OUT 1) ex) 0xff : output 1 - 8 port all on ex) 0x0f : output 1 - 4 port on Output test enable (0 : disable, 1: enable) Model# change (Not available on RUN) Data: 1- 15 for preset# 1 - 15
4005
4006
4007
4008
★ Please refer to the operation manual of ParaMon PC software for details of parameter settings.
Monitoring
To monitor fastening data and I/O status, Click and go to There are three(3) real-time monitoring menu and one error history.
2.3.1 Current, Speed, Angle Speed cmd, Current cmd, Snug angle, and Torque/Angle 2.3.2 I/O : Input & output status 2.3.3 Network: RS-232, Ethernet & Remote server settings
2.3.4 Error : latest 8 error history