MD tool has the auto speed setting feature against torque setting not to provide any over torque by speed shock. This auto speed is safe speed on the hard joint condition. On the real application, this setting can be changed manually. Auto customizing feature provides most optimized parameter settings for saving cycle time on the real application.
Speed Torque
time
① Select Preset # to modify parameter settings ② Select one of Soft & Hard joint condition when it is obviously clear or both together when it is not clear to be clarified, then click START ③ Apply screw tightening several times until there is no more parameter changing on the simulation & modification window. Be sure that the fastening condition should be same during the process. The system changes parameter values by the previous fastening data. ④ Once there is no more changes on the simulation & modification window, click STOP to finish testing. ⑤ Click APPLY to apply the settings on the simulation & modification window. The setting can be modified by manually before applying them.