1365
TEST METHOD 9 DOWEL, SHELF STANDARD LOAD CAPACITY TEST
The load capacity is measured when the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure. Follow the conditions below to prevent the shelf supports or shelf board from falling off. Condition 1 The gap ( ※ ) between the shelf board and the side board shall be 1mm or less. ※ The gap between the shelf board and the shelf standard if shelf support is installed on a shelf standard. Condition 2 Use shelf board which has sufficient durability. Condition 3 The mounting hole processing dimension of the shelf dowel shall be less than the recommended mounting hole dimension. (The processing dimension may vary depending on the material of the side board.
Gap ※
Gap ※
Centre
Shelf board
P
Four shelf supports used for per shelf board
TEST METHOD 10 CATCH FORCE TEST
TEST METHOD 11 RETAINING FORCE TEST
The retaining force is measured when
The catch force is measured when the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure. Note: Misalignment of the mounting plate and body parts may cause the catch force to decrease or parts failure.
Mounting Plate
the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure. Note: Latch and strike must be engaged at least 2/3L or more (see the figure).
Strike
Horizontal direction
Body
P
Horizontal direction
2/3L or more
Latch part
Horizontal direction
L
Strike
TEST METHOD 12 DRAWER SLIDE LOAD CAPACITY TEST
TEST METHOD 13 DRAWER SLIDE LOAD CAPACITY TEST The load capacity is measured when the
The load capacity is measured based on the condition: • Continuous open- close: 50,000 cycles • Speed: 10 cycles per minute • Load is applied on the gravity point. The figure of load capacity includes drawer itself. • Drawer width: 350mm
Gravity point
240
weight (W) is applied at the centre of the drawer under the condition indicated by the figure and the operation to pull out the drawer by 240mm is repeated. The gap between drawer and cabinet shall be 1 mm or less.
Drawer
W
Cabinet
Centre
100
300
175
T 2
350
175
T
T 2
Calculation of slide centre of gravity
TEST METHOD 14 LEVELLING GLIDE LOAD CAPACITY TEST
TEST METHOD 15 PULL LOAD TEST
The load capacity is measured when the force (P) is applied in the direction of the arrow under the condition indicated in the figure. Product may break or distort if the contact surface is not flat.
The pull load capacity is measured when the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure.
P
Vertical direction
P
Flat contact surface
K-25 JEXAI1A
No.500 Catalogue
I-109
Made with FlippingBook - professional solution for displaying marketing and sales documents online