TEST METHOD 9 DOWEL, SHELF STANDARD LOAD CAPACITY TEST

The load capacity is measured when the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure. Follow the conditions below to prevent the shelf supports or shelf board from falling off. Condition 1 The gap ( ※ ) between the shelf board and the side board shall be 1mm or less. ※ The gap between the shelf board and the shelf standard if shelf support is installed on a shelf standard. Condition 2 Use shelf board which has sufficient durability. Condition 3 The mounting hole processing dimension of the shelf dowel shall be less than the recommended mounting hole dimension. (The processing dimension may vary depending on the material of the side board.

Gap ※

Gap ※

Centre

Shelf board

P

Four shelf supports used for per shelf board

TEST METHOD 10 CATCH FORCE TEST

TEST METHOD 11 RETAINING FORCE TEST

The retaining force is measured when

The catch force is measured when the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure. Note: Misalignment of the mounting plate and body parts may cause the catch force to decrease or parts failure.

Mounting Plate

the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure. Note: Latch and strike must be engaged at least 2/3L or more (see the figure).

Strike

Horizontal direction

Body

P

Horizontal direction

2/3L or more

Latch part

Horizontal direction

L

Strike

TEST METHOD 12 DRAWER SLIDE LOAD CAPACITY TEST

TEST METHOD 13 DRAWER SLIDE LOAD CAPACITY TEST The load capacity is measured when the

The load capacity is measured based on the condition: • Continuous open- close: 50,000 cycles • Speed: 10 cycles per minute • Load is applied on the gravity point. The figure of load capacity includes drawer itself. • Drawer width: 350mm

Gravity point

240

weight (W) is applied at the centre of the drawer under the condition indicated by the figure and the operation to pull out the drawer by 240mm is repeated. The gap between drawer and cabinet shall be 1 mm or less.

Drawer

W

Cabinet

Centre

100

300

175

T 2

350

175

T

T 2

Calculation of slide centre of gravity

TEST METHOD 14 LEVELLING GLIDE LOAD CAPACITY TEST

TEST METHOD 15 PULL LOAD TEST

The load capacity is measured when the force (P) is applied in the direction of the arrow under the condition indicated in the figure. Product may break or distort if the contact surface is not flat.

The pull load capacity is measured when the force (P) is gently applied in the direction of the arrow under the condition indicated by the figure.

P

Vertical direction

P

Flat contact surface

K-25 JEXAI1A

No.500 Catalogue

I-109