Cullen Technical Guide 2025

/

PSTS

Multiple Connections

Layout of Paslode STS 8.0mm In Bottom Chords

Figure 1 – Bottom Chords Depths of 72mm, 84mm or 97mm

II

S

S

S

II

150

Figure 2 – Bottom Chords Depths of 122mm, 147mm, 172mm, 197mm or 222mm Figure 4 – Top Chords/Webs of Depths 122mm, 147mm, 172mm, 197mm or 222mm

56

S

S

S

56

150

Layout of Paslode STS 8.0mm In Webs & Top Chords

II

Figure 3 – Top Chords/Webs of Depths 72mm, 84mm or 97mm

600

II

300

56

Figure 4 – Top Chords/Webs of Depths 122mm, 147mm, 172mm, 197mm or 222mm

600

600

56

300

FASTENERS CAN BE INSTALLED FROM ONE SIDE OF GIRDER TRUSS For further information please contact Technical Support.

Installation Instructions Stage 1

Stage 2

Stage 3

Stage 4

S

X

X

Install using an impact driver.

Bring the underside of the washer head flush with the timber surface.

Always maintain the required minimum edge distance and spacing.

6.5mm Hex Head

8.0mm Hex Head

Select the correct fastener type and size.

Do not countersink or overdrive.

These values vary – please refer to relevant details.