HGG
Heavy Girder To Girder
The HGG hanger is designed to support multiple ply girder trusses from a vertical web in high load situations. Features & Benefits — New and improved design using PSTS screws simplifies the installation — Allows fixings into vertical web only — Additional side fixings allows for greater uplift capacity
UKTA–21/0008 UKTA - 21/0008
ETA–20/0999
Material Specification — Galvanised mild steel – Z275
Fixings 40No Paslode PSTS 6.5 x 65mm supplied with hanger
Dimensions (mm)
W
Available Sizes
Incoming Truss Width
Minimum Header Width (mm)
Hanger Width (W) (mm)
Hanger Depth (H) (mm)
Product Code
HGG–80 HGG–102 HGG–153 HGG–200
2No 35 2No 47 3No 47 4No 47
97
80
519 508 542 519
122 147 197
102 153 200
H
Incoming and header trusses must be connected together to act as a single unit
In Situ
MIN HEADER WIDTH
125
MIN 40MM
— Minimum edge distances must be met to achieve full capacity. — Please ensure vertical end members are stepped back to allow room for screw heads. — Supported member should be positioned to the back of the hanger. — Maximum allowable gap of 3mm.
(Plates omitted for clarity)
Load Data
Fixings
Characteristic Capacity (kN)
Product Code
PSTS 6.5 x 65mm
Solid Timber Header (Min TR26)
Uplift
Header
Incoming
HGG–80, HGG–102, HGG–153, HGG–200
34
6
11.40*
64.60
*Minimum 122mm deep bottom chord required to achieve the full uplift capacity
The latest most up to date version will always be online and not in print or in downloaded pdf.
106
Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk