TA Truss Anchor
The TA secures trussed rafters to 2 ply wall plates or head binders whilst providing a positive fixing on two planes. Features & Benefits — Eliminates damage from skew nailing into the wall plate — “Push on” fit allows truss anchor to be retained in position prior to nailing — Optional triangular nail holes for enhanced performance
UKTA–21/0009 UKTA - 21/0009
ETA–20/1000
Material Specification — Galvanised mild steel – Z275
Fixings Code
Description
Box Qty
547389 141185
3.4 x 35mm Square Twist Nails – LOOSE 3.4 x 35mm Square Twist Nails – COLLATED*
500
2,500
*For use with Paslode PPNXi
W
Available Sizes
Dimensions (mm)
Product Code
Truss Width (mm)
W (mm)
TA–38 TA–50
35 47
113 113
In Situ
150
Double wall plate required for all installations (min 75mm) unless using in a timber frame application where the framing anchor can be fitted to the head binder.
45
30
Standard Installation (Fill all circular nail holes)
Enhanced Installation (Fill all nail holes)
2No Truss Anchors (Dependant on truss heel)
1
1
1
3
3
2
2
2
3
(Plates omitted for clarity)
Load Data
Characteristic Capacity (kN)
Fixings (3.4 x 35mm)
Product Code
Installation
Load Direction
Solid Timber Header (Min C16)
Header
Incoming
1 2 3 4 1 2 3 4
3.48 (6.96**) 3.39 (6.78**) 0.78 (1.35**) 0.57 (1.35**) 7.54 (15.08**) 4.17 (8.34**) 2.10 (4.29**) 2.19 (4.29**)
TA–38, TA–50
STANDARD INSTALL
4
4
TA–38, TA–50 ENHANCED INSTALL
9
8
**Values for 2No truss anchors
The latest most up to date version will always be online and not in print or in downloaded pdf.
122
Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk
Made with FlippingBook Annual report maker