TA–1 Framing Anchor

The TA–1 provides a positive connection on two planes without encroaching into the internal space. Features & Benefits — Eliminates damage from skew nailing — Single anchor means the part is not width dependant

UKTA–21/0009 UKTA - 21/0009

ETA–20/1000

Material Specification — Galvanised mild steel – Z275

Fixings Code

Description

Box Qty

547389 141185

3.4 x 35mm Square Twist Nails – LOOSE 3.4 x 35mm Square Twist Nails – COLLATED*

500

2,500

*For use with Paslode PPNXi

Dimensions (mm)

40

100

160

In Situ

100

Double wall plate required for all installations (min 75mm) unless using in a timber frame application where the framing anchor can be fitted to the head binder.

40

1No TA–1 standard installation**

1No TA–1 installed to opposite side**

1No TA–1 installed to outer face**

1

1

1

3

3

2

2

**Also suitable to fix to the outside of the wall plate depending on truss heel detail.

3

2

(Plates omitted for clarity)

Load Data

Characteristic Capacity (kN)

Fixings (3.4 x 35mm)

Product Code

Load Direction

Solid Timber Header (Min C20)

Header

Incoming

1 2 3

3.12 1.55 1.84

TA–1

5

5

All values are per anchor.

The latest most up to date version will always be online and not in print or in downloaded pdf.

124

Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk