RA Range Restraint Angle Range

Load Data

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Hanger Type

Masonry Crushing Strength

Uplift*

I–Joist

2.8N/mm 2

3.5N/mm 2

7.0N/mm 2

RA

6

7.11 7.11 7.11

9.10

11.38 28.14 14.35

11.38 28.14

HRAD RADS

12

22.51 11.48

9 14.35 *Uplift only applicable when hangers are fully built in with a minimum of 675mm of fully cured masonry above the base plate.

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Hanger Type

Masonry Crushing Strength

Uplift*

Open Web Joist

2.8N/mm 2

3.5N/mm 2

7.0N/mm 2

RA

6

7.11 7.11 7.11

9.10

11.38 28.14 14.35

11.38 28.14

HRAD RADS

12

22.51 11.48

9 14.35 *Uplift only applicable when hangers are fully built in with a minimum of 675mm of fully cured masonry above the base plate.

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Hanger Type

Masonry Crushing Strength

Uplift*

LVL/GL

2.8N/mm 2

3.5N/mm 2

7.0N/mm 2

RA

6

7.11 7.11 7.11

11.49 27.34 11.48

14.37 34.18 14.35

14.37 34.18

HRAD RADS

12

9 14.35 *Uplift only applicable when hangers are fully built in with a minimum of 675mm of fully cured masonry above the base plate.

Incorrect Installation

Do not use the RA range with trussed rafters.

Do not install the RA range onto a timber wall plate.