Cullen Technical Guide 2026

Floors

HUH (I–Joist Applications) Heavy Universal Hanger Standard Installation Instructions – I–Joist Header without Backer Block

Stage 1

Stage 2

Stage 3

Stage 4

Wipe over top tabs to give a flush fit to the joist.

Nail top tabs into top flange of joist – Min 2No 3.4 x 35mm square twist nails into rear ply and 1No 3.4 x 35mm square twist nail into front ply per leg.

Position hanger flush with underside of joist.

Face nail to top and bottom flanges using 14No 3.4 x 35mm square twist nails in total.

Enhanced Installation Instructions – I–Joist Header with Backer Block

Stage 1

Stage 2

Stage 3

Stage 4

Nail top tabs into top flange of joist – Min 2No 3.4 x 35mm square twist nails into rear ply and 1No 3.4 x 35mm square twist nail into front ply per leg.

Fill all round and triangular nail holes to header and backer face with 3.4 x 35mm square twist nails.

Wipe over top tabs to give a flush fit to the joist.

Position hanger flush with underside of joist.

Backer block installed as per I–Joist manufacturer’s guidelines.

HUH-W-220-235 Installation Guidance Top Flange Nailing

1. Diamond nail holes are to be nailed for joist depths <= 225mm​ 2. Circular holes are to be nailed for joist depths >225mm ​​ *All circular holes on the face of the header must be nailed as standard, excluding the HUH-W-220-235 with joists over 225mm deep, where 6 circular holes at the top flange are replaced by 6 diamond holes.​ *Triangular holes are for Enhanced Installations

1.

2.

The latest most up to date version will always be online and not in print or in downloaded pdf.

34

Technical support 01592 771132 / technical@itwcp.com / https://www.itwcoe.com