HRS Head Restraint Screw
Scan or click to view installation video
NEW
The HRS is used for securing non-load bearing partitions to the floor structure and provides lateral restraint to the panel. Features & Benefits — Allows for joist/truss deflection — Reduces plasterboard cracking and fixing defects
— Screw design reduces squeaks — Plasterboard can be pre-installed — Guide to support installation
In Situ
— Requires no pre-drilling Material Specification — Carbon steel screw — PA recyclable guide
Approvals — Meets NHBC Technical requirements
Dimensions (mm)
100
30
Load Data
Characteristic lateral load capacity per fixing (kN) Timber frame partition (C16min grade) - attached to engineerred joist
Maximum Gap Between (mm)
Product Code
Partition and joist or Partition and plasterboard (15mm max plasterboard)
Code
Description
Box Qty
546496
15
1
546496
PSTS 6.5 x 100 + Guide
100
Installation Instructions - Plasterboard pre-installed *Drive the screw until the thread is fully embedded in the joist
*Install the HRS at 1200mm centres maximum and ensure a minimum of two HRSs per partition, with a recommended edge distance of 200mm
1
2
3
4
5
Drive the screw up (do not overdrive the screw)
Position the guide against the partition header
Partially drive the screw vertically into the header
Remove the guide
Insert a screw into the guide
The latest most up to date version will always be online and not in print or in downloaded pdf.