UH (I–Joist Applications)

Universal Hanger UH (300) & UZ–Clip – I–Joist Header with Backer Block or Solid Header

Load Data

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Hanger Width (mm)

Header

Header

Incoming

Uplift

(Width Dependent Only)

Face

Top

Solid Flange I–Joist, LVL Flange I–Joist

39 – 65 72 – 100

24 24

0 0

2 2

2.00 2.00

12.49 16.90

MHE (620) & UZ–Clip – I–Joist Header with Backer Block or Solid Header

Load Data

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Hanger Width (mm)

Header

Header

Incoming

Uplift

Solid Flange I–Joist, LVL Flange I–Joist

(Width Dependent Only)

Face

Top

122 – 198

24

0

2

2.00

30.58