UH (Open Web Applications) Universal Hanger
Standard Installation – Open Web Header
See Page 61 For Installation Instructions — Fill all red holes as indicated for this installation — No backer block/plywood gusset required — Top tabs to be wiped over and nailed — Additional triangular holes into face only required for solid headers
Additional triangular holes into incoming joist only required for enhanced uplift. (for details see page 59)
Load Data
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
Hanger Depth (mm)
Header
Incoming
Uplift
Open Web Header
(Depth Dependent)
Face
Top
195 220 235 300
8 8 8 8
2 2 2 2
2 4 4 4
1.98 3.97 3.97 3.97
14.19 14.19 13.23 13.64
Enhanced Installation – Solid Header
See Page 61 For Installation Instructions
SNAP OFF OPTION
— Fill all red holes as indicated for this installation — All nail holes filled into solid header (including triangular) — Top tabs to be wiped over and nailed or snapped off to give face fix only option
Additional triangular holes into incoming joist only required for enhanced uplift. (for details see page 59)
Load Data
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
Hanger Depth (mm)
Header
Solid Header
Incoming
Uplift
GL (Min GL28h)
(Depth Dependent)
Face
Top
LVL
195 220 235 300
14 18 18 22
2 (0**) 2 (0**) 2 (0**) 2 (0**)
2 4 4 4
1.98 3.97 3.97 3.97
16.84 19.69 22.16 22.16
15.25 18.65 21.58 22.17
**No fixings required when using snap off option