UH (Open Web Applications) Universal Hanger
Enhanced Installation – Open Web Header with Plywood Gusset
See Page 62 For Installation Instructions — Fill all red holes as indicated for this installation
— 18mm plywood gusset should be screwed into open web header with the appropriate screws – see installation instructions for more information — All nail holes filled into plywood gusset (including triangular) — Top tabs snapped off to give face fix only fixing
Additional triangular holes into incoming joist only required for enhanced uplift. (for details see below)
Load Data
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
Hanger Depth (mm)
Header
Incoming
Uplift
Open Web Header / 18mm
(Depth Dependent)
Face
Top
195 220 235 300
14 18 18 22
0 0 0 0
2 4 4 4
1.98 3.97 3.97 3.97
16.84 19.69 22.16 22.16
Enhanced Uplift
— Fill all red holes as indicated for this installation — Fixings into the incoming joist are required to resist uplift — Increased uplift figures can be achieved by nailing the additional triangular nail holes into the incoming member – solid incoming or web stiffeners are required
Load Data
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
Hanger Depth (mm)
Incoming
Uplift
(Depth Dependent) 195
6 8
5.97 7.97
220 – 300
195MM
220 – 300MM
Near side
Far side