Cullen Technical Guide 2024

/

UH (Open Web Applications) Universal Hanger

Standard Installation Instructions – Open Web Header

Stage 1

Stage 2

Stage 3

Stage 4

Position hanger against face of open web joist with locating tab tight to underside of joist.

Face nail to top and bottom chords using 8No 3.4 x 35mm square twist nails in total.

Wipe over top tabs to give a flush fit to the joist.

Nail top tabs into top chord of joist – 1No 3.4 x 35mm square twist nail per tab.

Enhanced Installation Instructions – Solid Header

Stage 1

Stage 2

Stage 3

Option 1

Option 2

Position hanger against face of joist with locating tab tight to underside of joist.

Fill all round and triangular nail holes to header with 3.4 x 35mm square twist nails.

Bend top tab forward and snap off.

Wipe over top tabs to give a flush fit to the joist. Nail top tabs into top chord of joist – 1No 3.4 x 35mm square twist nail nail per tab.

The latest most up to date version will always be online and not in print or in downloaded pdf.

61

Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk