HUH (I–Joist Applications) Heavy Universal Hanger Standard Installation Instructions – I–Joist Header without Backer Block

Stage 1

Stage 2

Stage 3

Stage 4

Position hanger flush with underside of joist.

Face nail to top and bottom flanges using 14No 3.4 x 35mm square twist nails in total.

Wipe over top tabs to give a flush fit to the joist.

Nail top tabs into top flange of joist – Min 2No 3.4 x 35mm square twist nails into rear ply and 1No 3.4 x 35mm square twist nail into front ply per leg.

Enhanced Installation Instructions – I–Joist Header with Backer Block

Stage 1

Stage 2

Stage 3

Stage 4

Position hanger flush with underside of joist.

Fill all round and triangular nail holes to header and backer face with 3.4 x 35mm square twist nails.

Wipe over top tabs to give a flush fit to the joist.

Nail top tabs into top flange of joist – Min 2No 3.4 x 35mm square twist nails into rear ply and 1No 3.4 x 35mm square twist nail into front ply per leg.

Backer block installed as per I–Joist manufacturer’s guidelines.