HUH (Open Web Applications) Heavy Universal Hanger
Enhanced Uplift
— Fill all red holes as indicated for this installation — Fixings into the incoming joist are required to resist uplift — Increased uplift figures can be achieved by nailing the additional triangular nail holes into the incoming member – solid incoming or full width vertical required
Near side
Far side
195 – 400MM
Incorrect Installation
BETWEEN 20-40MM
Hanger side flanges/plates omitted for clarity
Hanger side flanges/plates omitted for clarity
2No end verticals required to achieve full uplift capacity.
Single end verticals can be used if the gap between the back of the hanger and the vertical is between 20 – 40mm.
Do not use HUH for enhanced uplift when using trimmable ends
Load Data
Hanger Depth (mm)
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
(Depth Dependent Only)
Incoming
Uplift
195 – 400
8
7.97
The latest most up to date version will always be online and not in print or in downloaded pdf.