HUH (Open Web Applications) Heavy Universal Hanger

Enhanced Uplift

— Fill all red holes as indicated for this installation — Fixings into the incoming joist are required to resist uplift — Increased uplift figures can be achieved by nailing the additional triangular nail holes into the incoming member – solid incoming or full width vertical required

Near side

Far side

195 – 400MM

Incorrect Installation

BETWEEN 20-40MM

Hanger side flanges/plates omitted for clarity

Hanger side flanges/plates omitted for clarity

2No end verticals required to achieve full uplift capacity.

Single end verticals can be used if the gap between the back of the hanger and the vertical is between 20 – 40mm.

Do not use HUH for enhanced uplift when using trimmable ends

Load Data

Hanger Depth (mm)

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

(Depth Dependent Only)

Incoming

Uplift

195 – 400

8

7.97